FRIIA Service manual
Page 32
ISSUE
PROBABLE CAUSE
SOLUTION
Too low CO
2
volume
CO
2
pressure too low
Restore correct CO
2
pressure (typically about 4 bar / 60 psi)
CO
2
cylinder empty
Replace CO
2
cylinder
Water temperature too high because cooling capacity is
exceeded by over drawing
See refrigeration/equipment specifications vs. volume
requirements and reduce amount of glasses taken per given
time of install higher volume unit.
Air trapped inside the carbonator
Open carbonator vent check valve, pulling ring, until water
streams out.
CO
2
only flows out from faucet
Carbonator Electrode connection to wiring harness defective,
loose electrical connection and/or open circuit
Tighten connection, repair carbonator wiring harness
connection and check electrode connection at E.C.U.
The carbonation pump turns continuously
No water is entering or the water filter is blocked or Hoses and
pipe fittings into the carbonator are obstructed.
Disassemble and clean it.
Check valve on carbonator water inlet failed open
Verify correct behavior of the non-return (check valve)
assembled on the carbonator water inlet.
Inoperable water pump/ motor.
Check for proper line voltage on component terminals.
Replace water pump/ motor if defective.
Electronic Control Unit (E.C.U.) defective.
Replace E.C.U. assembly.
E.C.U. in timeout (> 240” continuous operation)
Reset Timeout protection switching off equipment and waiting
60” before repower it.
Short cycling of water pump
motor
Carbonator Electrode connection to wiring harness defective or
reversed.
Repair carbonator wiring harness connection and check
electrode connection at E.C.U.
Continuous dripping
from the outlets
Few drops, mainly after soda dispensing is normal. If dripping is
continuous faucet or internal electrovalve could be dirty.
Disassemble the internal solenoid valve and clean it.
Still water comes out
carbonated
Internal check valve could be dirty.
Disassemble check valve and clean it. Replace if needed.
Summary of Contents for FRIIA 1000860 Series
Page 33: ...8 WIRING DIAGRAM FRIIA Service manual Page 33...
Page 34: ...9 HYDRAULIC DIAGRAM FRIIA Service manual Page 34...
Page 35: ...FRIIA Service manual Page 35 Functional Hydraulic Schematic...
Page 37: ...11 2 Outer frame FRIIA Service manual Page 37...
Page 38: ...11 3 Top bracket FRIIA Service manual Page 38...
Page 39: ...11 4 Front electronic bracket FRIIA Service manual Page 39...
Page 40: ...11 5 Pump and Electrovalve brackets FRIIA Service manual Page 40...
Page 41: ...11 6 Base FRIIA Service manual Page 41...
Page 42: ...CABLES AND HARNESSES FRIIA Service manual Page 42 620 UK 115Vac 621 622 623...
Page 43: ...FRIIA Service manual Page 43...
Page 44: ...FRIIA Service manual Page 44...
Page 45: ...FRIIA Service manual Page 45...
Page 46: ...FRIIA Service manual Page 46...