7. TROUBLESHOOTING - DIAGNOSTIC GUIDE:
FRIIA Service manual
Page 31
ISSUE
PROBABLE CAUSE
SOLUTION
The compressor will
not start
Power failure
Check that there is voltage in the plug
Thermostat in the off position, or set to the minimum
Check wirings and adjust the thermostat position
Faulty thermostat
Check wirings replace the thermostat
The over-load protection of the compressor is faulty
Wait for compressor cool down and replace it
The starting relay is faulty
Check wiring replace the faulty component
The starting capacitor is faulty
Check wiring replace the faulty component
The compressor is faulty
Check wiring replace the faulty component
The water is cold but
the appliance is operating
excessively or
non-stop
Poor ventilation
Place the appliance away from the wall
The condenser is dirty or covered
Clean the condenser or free it from obstructions
The thermostat is on maximum cold position
Adjust thermostat knob in the middle rotational range
Ambient temperature is higher than 32°C
It is normal that the appliance works at a continuously high
room temperature
The compressor
works continuously,
but the water is not
cold
Gas leak from the cooling system
Contact a specialized technician (refrigerator repairman) or
Marco Beverage Systems
The compressor is faulty
Check wirings and voltage on compressor terminals and
replace the faulty component if needed.
Too much noise coming
from the equipment,
but it is working normally
The machine is not perfectly horizontal
Level the appliance using the adjustable feet
Hoses and wirings are in contact with housing some parts inside
the equipment and generate noise and vibrations.
Check and reposition hoses and wirings, making sure they do
not touch any other parts.
Cold water comes out
slowly or not at all
Water inlet supply shutoff valve closed or faulty electrovalves
closed, water filter fouled/clogged.
Open water inlet supply line shutoff valve, check electrovalves
and anti-flooding device replace electrovalves ; replace filter
or cartridge.
Low pressure of the inlet net water
Take steps to increase the net pressure (e.g. booster pump)
The thermostat is out of tolerance range or defective.
Waiting for ice melting down. Replace Alublock thermostat.
Summary of Contents for FRIIA 1000860 Series
Page 33: ...8 WIRING DIAGRAM FRIIA Service manual Page 33...
Page 34: ...9 HYDRAULIC DIAGRAM FRIIA Service manual Page 34...
Page 35: ...FRIIA Service manual Page 35 Functional Hydraulic Schematic...
Page 37: ...11 2 Outer frame FRIIA Service manual Page 37...
Page 38: ...11 3 Top bracket FRIIA Service manual Page 38...
Page 39: ...11 4 Front electronic bracket FRIIA Service manual Page 39...
Page 40: ...11 5 Pump and Electrovalve brackets FRIIA Service manual Page 40...
Page 41: ...11 6 Base FRIIA Service manual Page 41...
Page 42: ...CABLES AND HARNESSES FRIIA Service manual Page 42 620 UK 115Vac 621 622 623...
Page 43: ...FRIIA Service manual Page 43...
Page 44: ...FRIIA Service manual Page 44...
Page 45: ...FRIIA Service manual Page 45...
Page 46: ...FRIIA Service manual Page 46...