5.3.3 R290 Refrigerant circuit
FRIIA Service manual
Page 19
What are R290 refrigerant circuit components?
• Compressor and copper pipes welded on the compressor;
• Priming pipe
• Suction pipe
• Filling pipe with its cap.
• Condenser and condenser pipes, priming pipe from compressor and filter pipe to
filter/drier.
• Filter/Drier.
• Capillary pipe, the lamination device, welded between the filter/drier out and the
evaporator inlet.
• Evaporator, the stainless steel tube, with a 8mm diameter integrated in the Alublock.
• Suction pipe, welded between evaporator and compressor.
Summary of Contents for FRIIA 1000860 Series