FRIIA Service manual
Page 30
Carbonator NRV cleaning and replacement (CO2 in cold still water)
Sporadically, dust or iron particles may be present in the pipes or coils of the chiller or may
come from the outer tubes during the first installation or during maintenance operations to
external filters. In the case of leakage from NRV (CO2 in cold still water), the NRV should
be removed checked and cleaned.
Please ensure the CO2 is disconnected and purged from the machine.
This can be done removing the internal top bracket sub-assembly with all components, as
described previously, giving access to the carbonator.
Identify the two NRV; the CO2 NRV (a) is the one directly connected to the CO2 inlet; the
water inlet NRV (b) is the one connected to the alublock coil.
Undo the hydraulic connection on the inlet of the NRV (b) and with a spanner remove the
body of NRV.
During removal, be careful not to damage the plunger and threads and note the assembly
orientation of the internal components.
Inspect for damage and/or residuals on the plunger spring (c) and on the seal (d). Replace
the plunger if needed.
For reassembly, repeat the same operations in reverse order
.
a
b
c
d
Summary of Contents for FRIIA 1000860 Series
Page 33: ...8 WIRING DIAGRAM FRIIA Service manual Page 33...
Page 34: ...9 HYDRAULIC DIAGRAM FRIIA Service manual Page 34...
Page 35: ...FRIIA Service manual Page 35 Functional Hydraulic Schematic...
Page 37: ...11 2 Outer frame FRIIA Service manual Page 37...
Page 38: ...11 3 Top bracket FRIIA Service manual Page 38...
Page 39: ...11 4 Front electronic bracket FRIIA Service manual Page 39...
Page 40: ...11 5 Pump and Electrovalve brackets FRIIA Service manual Page 40...
Page 41: ...11 6 Base FRIIA Service manual Page 41...
Page 42: ...CABLES AND HARNESSES FRIIA Service manual Page 42 620 UK 115Vac 621 622 623...
Page 43: ...FRIIA Service manual Page 43...
Page 44: ...FRIIA Service manual Page 44...
Page 45: ...FRIIA Service manual Page 45...
Page 46: ...FRIIA Service manual Page 46...