FRIIA Service manual
Page 24
Carbonation Pump Electronic Control Unit
To replace the carbonation pump ECU, disconnect the wirings from the ECU, and undo the
screw (a) located on the top side of the bracket; the ECU can be removed for maintenance.
During removal, be careful not to damage the electric wiring or the refrigeration group
pipes.
For reassembly, repeat the same operations in reverse order paying attention to
assembling the electrical connections in the correct order.
a
GN/YE Ground connection
RD – Carbonator Level mn
BK – Carbonator Level max
BK – Carbonation Pump Motor
BK – Carbonation Pump Motor
/ BU – 230Vac (Piggy back) from main switch
BU – 230 Vac (Piggy back) to Main Elecronic Board
BN – 230 Vac (Piggy back) to Main Elecronic Board
\ BN – 230Vac (Piggy back) from main switch
NC
NC
NC
NC
Summary of Contents for FRIIA 1000860 Series
Page 33: ...8 WIRING DIAGRAM FRIIA Service manual Page 33...
Page 34: ...9 HYDRAULIC DIAGRAM FRIIA Service manual Page 34...
Page 35: ...FRIIA Service manual Page 35 Functional Hydraulic Schematic...
Page 37: ...11 2 Outer frame FRIIA Service manual Page 37...
Page 38: ...11 3 Top bracket FRIIA Service manual Page 38...
Page 39: ...11 4 Front electronic bracket FRIIA Service manual Page 39...
Page 40: ...11 5 Pump and Electrovalve brackets FRIIA Service manual Page 40...
Page 41: ...11 6 Base FRIIA Service manual Page 41...
Page 42: ...CABLES AND HARNESSES FRIIA Service manual Page 42 620 UK 115Vac 621 622 623...
Page 43: ...FRIIA Service manual Page 43...
Page 44: ...FRIIA Service manual Page 44...
Page 45: ...FRIIA Service manual Page 45...
Page 46: ...FRIIA Service manual Page 46...