Mantracourt Electronics Limited
T24 Technical Manual
68
RemoteBattAction
105
Select the action to trigger when the remote device
reports low battery.
Value
Description
0
None
1
Minimum Full Scale
2
Maximum Full Scale
3
Minimum Output
4
Maximum Output
5
Half Full Scale
6
Hold Last Output
UINT8
RW
Smoothing
106
Select whether to smooth the output. When activated this
will result in a latency of the interval between data
packets arriving.
UINT8
RW
PairWait
107
The time to wait in seconds when pairing after pressing the
Pair switch.
UINT8
RW
BoundDataTag
108
The Data Tag of the data being used to set the output.
UINT16
RW
ZeroValue
109
Set or read the system zero value which is subtracted from
the value of the data arriving before mapping to the analog
output.
FLOAT
RW
DoWake
110
Whether to wake paired module on power up. (1 or 0)
UINT8
RW
BoundID
111
Set or read the ID of the bound device. Used to wake the
remote device.
BINARY 3 Bytes
RW
NOTE: All changes require a SAVE command to enable them to survive through power cycle or RESET command.
Connections
Depending on the analog output device you have you will need to refer to one of the two following diagrams:
T24-AO1
Mode
Activity
Timeout
Error
Batt Low
Vout +
Vout -
I Sink +
I Sink -
I
I Source -
0V
+V
1 2 3 4 5 6 7 8
ON
OFF
SW2
PAIR
9 to 36V dc
Supply
T24-AO1i
Vout +
Vout -
I Sink +
I Sink -
I
I Source -
GND
Timeout
Error
Batt Low
+V
Input Zero
Mode
Activity
Timeout
Error
Batt Low
0V
+V
9 to 36V dc
Supply
1 2 3 4 5 6 7 8
ON
OFF
SW2
PAIR