Mantracourt Electronics Limited
T24 Technical Manual
37
Note that default value is set to last 2 bytes of ID.
UserGain
79
Set the gain to apply to the input
FLOAT
RW
UserOffset
79
Set the offset to apply to the input
FLOAT
RW
RawValue
70
Read the raw uncalibrated input.
FLOAT
R
Value
72
Reads the user calibrated output.
FLOAT
R
IgnoreFirstPulse
82
Set to 1 to ignore the first pulse detected after power
up or wakeup
UINT8
RW
PPR
83
Pulses per revolution. Indicates how many pulses the
input will receive per revolution when in RPM mode. (1
to 100)
UINT8
RW
EdgeType
84
Select the input edge to trigger on
Value
Definition
0
Falling
1
Rising
UINT8
RW
OutputType
85
Select the input edge to trigger on (0 to 3)
Value
Definition
0
Frequency (Hz)
1
RPM
1
Interval (s)
1
Counter
UINT8
RW
InputFilter
109
Enter a time in milliseconds to act as a debounce
filter. Input pulses arriving within this time of the
previous input will be ignored.
UINT16
RW
DigitalOut
108
Read or set the digital output state.
Value
Definition
0
Turn digital output off
1
Turn digital output on
2
Make digital output mirror the LED
state (V1.05 and later)
FLOAT
RW
Status
74
Live status where the bit values indicate status. The
following table shows the decimal bit values and their
meaning.
Bit Value
Definition
1
STATUS_SHUNT_CAL
2
STATUS_INPUT_INTEGRITY
4
Reserved
8
Reserved
16
STATUS_POWER_UP
32
STATUS_BATT_LOW
64
STATUS_DIGITAL_INPUT
128
STATUS_DIGITAL_OUTPUT
Reset
54
Restarts the device and utilises new channel and
encryption keys if those have been changed and saved.
Command
Save
55
Save any changes made to parameters. Required
before power cycling or issuing a Reset command.
Requires 500mS recovery time after executing.
Command
Wake
50
Wake the module from sleep
Command
Sleep
56
Sends the module to Sleep
Command
Pause
57
Stops the output streaming to allow configuration
Command
Resume
59
Streaming continues.
Command
StayAwake
58
No function other than to reset SleepDelay timer
Command
ResetCounter
64
No function other than to reset the counter when in
counter mode
Command
ResetTrigger
118
Enter Data Tag to watch for that will reset the counter
when in count mode
UINT16
RW