T24 Technical Manual
52
ZeroBand
72
Set or read the band within which zero will be
displayed. As soon as the value exceeds ±
ZeroBand
the
actual value will be displayed. This will effectively
mask small changes after taring the device.
FLOAT
RW
Overload
73
Set or read the value of the display above which
instead of the value being displayed 'Overload' will be
displayed.
FLOAT
RW
ScaleInLo
75
Set or read a low input value at which you know what
display you require. Default = 0
FLOAT
RW
ScaleInHi
77
Set or read a high input value at which you know what
display you require. Default = 1
FLOAT
RW
ScaleDisplayLo
76
Set or read a low display value for the input value
stated in
b
. Default = 0
FLOAT
RW
ScaleDisplayHi
78
Set or read a high display value for the input value
stated in
ScaleInHi
. Default = 1
FLOAT
RW
OpMode
122
Selects the operational mode.
Value
Description
0
Items Mode
Each of the configured input values
are displayed one at a time and the
Next button can be used to step
through them.
1
Result Mode
The input values are summed and
displayed.
UINT8
RW
F1Data
128
Set or read what data to transmit when the F1 key is
pressed.
Value
Description
0
Always Gross
The gross value will be transmitted
even if the display shows a zeroed net
reading.
1
As Displayed
The gross or net value will be
transmitted depending on what is
selected at the time.
UINT8
RW
F1DataTag
127
Set or read the 2 byte Data Tag to use in the Data
Provider packet that is transmitted when the F1 key is
pressed.
UINT16
RW
ExtZeroDataTag
80
Set or read the 2 byte Data Tag of the Data Provider
Packet that will supply a system zero value. This value
will be subtracted from the gross or net summed
values. This allows the same handheld to be used with
different sets of data providers each supplying its own
system zero value.
UINT16
RW
ExtZeroID
100
Set or read the ID of the device acting as external
system zero.
BINARY 3
Bytes
RW
MotionBand
123
Specify an engineering units band that the readings
must stay within for the duration of the
MotionTime
for the reading to be considered steady.
FLOAT
RW
MotionTime
124
Specify the duration in seconds for the motion
detection to operate.
UINT8
RW
MsgDuration
125
Specifies the duration in milliseconds that messages
are displayed. i.e. the message that shows
Input 1
or
Input 2
as items are selected.
UINT16
RW
ItemDuration
126
Specifies the duration in seconds that individual item
UINT8
RW