Mantracourt Electronics Limited
T24 Technical Manual
51
Parameter List
Parameter
Command
Number
Description
Native
Data
Type
Read /
Write
ID
3
Read the unique identifier ID for this device. (3 bytes)
BINARY 3
bytes
R
Version
53
Read the firmware version.
FLOAT
R
Channel
11
Radio Channel
UINT8
RW
EncKey
15
The radio encryption key to operate on. Requires
power cycle or Reset to enable.
Not supported in this
release.
BINARY
16 Bytes
RW
Power
12
Set or read the output power level. (0-100%)
UINT8
RW
Name
10
Set or read a user defined name. (11 characters)
STRING
11 Bytes
RW
Model
51
Read the model number of the device.
STRING
11 Bytes
R
UseCSMA
18
Select whether to use
Carrier Sense Multiple Access
techniques on transmission
.
Value
Description
0
Disabled
The
Carrier Sense Multiple Access
will be
disabled.
NOT RECOMMENDED
1
Enabled
The
Carrier Sense Multiple Access
will be
enabled.
See
Unslotted CSMA/CA
in
Appendix A
UINT8
RW
OffDelay
62
Time period in seconds before switching off if no
button is pressed. Setting to zero disables. Default = 5
UINT16
RW
AutoZero
63
Set or read the value limit which may be automatically
zeroed on startup.
When the handheld powers up and the input value is
within ±ZeroBand then the display will be zeroed. The
value of the input will be placed in AutoZero. i.e. from
this time onwards until powered off the display will
show
input value - AutoZero
FLOAT
RW
DoSleepWake
64
Set or read whether to perform wake and sleep on the
paired device when the handheld is powered up and
down. Default = 1
UINT8
RW
Timeout
65
Set or read the time in seconds that if exceeded
between receiving Data Provider packets from the
paired device will cause the display to show ------.
Default = 3
UINT16
RW
KeepAwakeInt
66
Set or read the interval in seconds between the
handheld transmitting
StayAwake
signals to the paired
device. Default = 5
UINT16
RW
DisplayUpdate
74
Set or read the interval between LCD updates. Default
= 300
UINT16
RW
PairWait
67
Set or read the period in seconds that the handheld
will wait for another device to pair when placed into
pair mode. Default = 5
UINT8
RW
Format
70
Set or read the format for the display. Here you can
define how the value will be displayed and where the
decimal point will appear. By including a non zero
value this will define the resolution of the displayed
value. i.e. the smallest step size of value changes.
Default = 0000.001
STRING 8
bytes
RW
ZeroSupp
71
Set or read whether to show the value on the display
with zero suppression.
0 = No zero suppression
1 = Zero suppression
UINT8
RW