background image

 13.04.2015     

  9

ItemPart No. Description

ItemPart No. Description

104225 Mankar-ONE, powerpack   

103824 Atomiser for MANKAR-TWO Flex   

104224 Mankar-TWO, powerpack   

1

103825 Motor-module for atomiser MANKAR-TWO Flex   

1

104220 Power pack housing Mankar-Roll

2

100478 Atomiser disc for segment atomiser   

2

100450 Storage battery 6V - 7Ah for MANKAR-Roll and Mini-Mantra  

3

101996 Segment-module for segmental atomiser incl. width adjustments  

3

104222 Spacer, power pack Mankar-Roll

4a

104940 Cable set, power pack Mankar-One

103947 Atomiser for MANKAR, One-S, Two-S, Flex   

4b

104941 Cable set, power pack Mankar-Two

5

100730 Fuse T3.15 Amp   

1

103946 Motor-Modul for atomizer MANKAR, One-S, Two-S   

6

100747 Fuse holder for glass fuse

7

100693 Socket, d=2,1 mm   

8

103286 Electronik, monitor with LED for MANKAR HQ and Roll   

9

104221 Mount for monitoring LED Mankar-Roll

10

104223 Mount, plastic, power pack Mankar-Roll

ItemPart No. Description

ItemPart No. Description

100527 Metering pump MANKAR-3, capacity 5 - 12 ml/min for MANKAR-110 GP  

 

100492 Metering pump MAFEX-3, capacity 2 - 20 ml/min   

1

100528 Pump housing for two-channel pump Metering pump MANKAR  

1

100493 Pump housing for single-channel pump Metering pump MAFEX  

2

102209 Rotor-3, chromed brass for piston pump MAFEX/MANKAR  

2

102209 Rotor-3, chromed brass for piston pump MAFEX/MANKAR  

3

102373 Sealing set for metering pump MANKAR-3/MAFEX-3   

3

102373 Sealing set for metering pump MANKAR-3/MAFEX-3   

4

101626 Repair set, metering pump MANKAR, pressure plate/wobble plate  

4

102436 Repair set, metering pump MAFEX, pressure plate/wobble plate  

5

102429 Repair set, metering pump MANKAR, metering adustment knop/ selectordisc  

5

102437 Repair set, metering pump MAFEX, selector/adustment knop  

6

100534 Cover for piston pump MAFEX/MANKAR   

6

100534 Cover for piston pump MAFEX/MANKAR   

2

 

1

 

3

 

4

 

5

 

6

 

2

 

1

 

3

 

4

 

5

 

6

 

 8 

 9 

10 

4a/b 



For units  

with  

two 

atomisers 

For units  

with  

one atomiser 

Summary of Contents for MANKAR

Page 1: ...ents and regional regulations for the use of herbicides and if necessary obtain approval from the responsible authorities e g environmental conservation agency Application is to be performed only by a competent user Remarks about usage of the unit Settings This system is not suitable for the application of water Use herbicides for testing the spray action and calibration of the flow rate Usage Pos...

Page 2: ...miser or other small parts Keep pesticide applicators and chemical substances away from children Assembly and preparation for first use Unit assembly is described for the individual models Before using the unit for the first time charge the battery for at least 16 hours Attention Always follow the sequence 1 Insert the plug jack into the charger socket 2 Plug the charging unit into a 230 V mains s...

Page 3: ...re width of the spray hood The optimal spray width under standard operating conditions is set by the manufacturer In the event of deviations the screw F can be loosened in order to move the width adjustment on the atomiser see drawing Further details regarding operating width adjustment can be found on the pages for the individual applicator units Cleaning Do not clean the applicator unit with a h...

Page 4: ... M N O Checking the output volume 1 Place an underlay e g cardboard or paper on the ground and prop up the unit on stands 2 Fill the chemical tank with herbicide undiluted 3 Disconnect the hose from the spray hood and place a measuring cup underneath 4 Open the shut off valve initially setting the metering adjustment knob to the maximum flow rate and simultaneously turning the wheel wait until the...

Page 5: ...round and prop up the unit on stands 2 Fill the chemical tank with herbicide undiluted 3 Disconnect the hose from the spray hood and place a measuring cup underneath 4 Open the shut off valve initially setting the metering adjustment knob to the maximum flow rate and simultaneously turning the wheel wait until the chemical solution is evenly applied 5 Set the chemical solution volume according to ...

Page 6: ... 7 104170 Cable holder plastic Mankar Roll 8 100998 Countersunk Philips head screw M 4 x 12 mm VA 9 100992 Washer M8 Ø8 4 mm VA 10 101145 Allen head screw M 8 x 16 mm VA 11 104140 3 way ball valve Mankar Roll 12 104130 Flow controller mount Mankar Roll 13 104131 Flow controller clips Mankar Roll 14 103319 Flow controller cpl PC HQ PC glass 35 0 mm 15 104100 Frame pump carrier Mankar Roll 16 104150...

Page 7: ... Handle bar bushing Mankar Roll 10 104200 Handle bar guide Mankar Roll 11 104501 Fully suspended drive flange Mankar Roll 12 104502 Friction bearing left Mankar Roll 13 104100 Frame pump carrier Mankar Roll 14 104161 Pump protection ring Mankar Roll 15 104160 Pump protection Mankar Roll 16 104503 Friction bearing right Mankar Roll 17 103477 Wheel 530 x 60 mm pneumatic tyred Mankar Roll 18 104112 A...

Page 8: ... 8 104315 Spring retainer for pressure spring Mankar Roll 9 104314 Pressure spring rotary joint Mankar Roll 10 104316 Bolt Allen key 10 x 130 mm VA Mankar Roll 11 101145 Allen head screw M 8 x 16 mm VA 12 104701 Height adjustment ONE Mankar Roll 13 104731 Width adjustment ONE ONE S Mankar Roll 14 103826 Allen head screw M 6 x 45 mm VA 15 103467 Filister head screw M 6 x 12 mm VA with Allen head 16...

Page 9: ... Mount plastic power pack Mankar Roll ItemPart No Description ItemPart No Description 100527 Metering pump MANKAR 3 capacity 5 12 ml min for MANKAR 110 GP 100492 Metering pump MAFEX 3 capacity 2 20 ml min 1 100528 Pump housing for two channel pump Metering pump MANKAR 1 100493 Pump housing for single channel pump Metering pump MAFEX 2 102209 Rotor 3 chromed brass for piston pump MAFEX MANKAR 2 102...

Page 10: ...spray one sided Incorrect width setting Undo screws F see page 3 and adjust the width setting to the left or right Atomiser drips Metering valve incorrectly adjusted Check setting see table Atomiser disc faulty contaminated Replace clean disc Atomiser spray discharge contaminated Clean Atomiser foams Residual water in the system Completely empty tank hose and segmental atomiser Air in hose Hose co...

Page 11: ...eclare under our sole responsibility that the following products are in conformity with the provisions of the following Council Directive 2006 42 EG Typ MANKAR ONE MANKAR TWO Hiske Weissmann Managing Director Geesthacht January 2020 _______________________ _________________________________ Place and date of signature Name title and signature ...

Reviews: