15.12.2014
4
Assembly
1.
Mount handle bar guide (A) on frame pump carrier (B).
2.
Screw height adjustment (C) on to spray hood (D).
3.
Fit height adjustment (C) to frame pump carrier (B) in
front of or behind wheel.
4.
Screw support stand (E) on to frame (in front of or behind
wheel depending on position of hood).
5.
Connect tank from holder (F) to pump intake hose.
6.
Connect chemical solution hose from hood (D) to hose
from frame pump carrier (B)
7.
Connect atomiser cables for spray hoods (D) to cable
harness from frame pump carrier (B).
8.
Connect cable harness for frame pump carrier (B) to
power pack (G)
Metering table
Roundup application rate at 20 °C
Metering
adjustment
knob
position
Spray width in cm
20
25
30
35
40
45
50
55
Litres
per
ha
1
-
-
-
-
-
-
A
A
2
-
A
B
C
D
E
F
G
3
B
D
E
F
H
I
J
K
4
D
F
H
J
K
M
N
O
Checking the output volume
1.
Place an underlay (e.g. cardboard or paper) on the
ground and prop up the unit on stands.
2.
Fill the chemical tank with herbicide - undiluted.
3.
Disconnect the hose from the spray hood and place
a measuring cup underneath.
4.
Open the shut-off valve, initially setting the metering
adjustment knob to the maximum flow rate and
simultaneously turning the wheel; wait until the
chemical solution is evenly applied.
5.
Set the chemical solution volume according to the
output table.
6.
Volume calibration: Collect the chemical solution from
50 wheel revolutions in a measuring cup. If the
desired volume is not reached, set a larger or
a smaller volume with the pump metering adjustment
knob.
7.
Perform volume calibration again.
8.
Reconnect the hose to the spray hood.
9.
The unit is now ready for use.
Maximum allowable wheel pressure 2.5 bar
MANKAR-ONE 45
MANKAR-ONE-S Flex
A
B
A
A
A
C
A
D
A
F
E
A
G
Collector receptacle for
draining the tank contents