background image

15.12.2014     

10

 

Troubleshooting 

 

Fault

 

Cause

 

Rectification

 

 

 

 

Atomiser disc does 
not rotate

 

Atomiser contaminated

 

Thoroughly clean atomiser, remove plant parts as 

necessary

 

Battery empty

 

Charge battery

 

Fuse blown

 

Replace fuse on power pack 

(Replacement fuses are located in the power pack 

housing)

 

No electrical contact

 

Check cable and connector contacts

 

Battery faulty

 

Install new battery

 

Atomiser motor faulty

 

Install new motor 

Connect the brown cable to Plus (+). 

 

Atomiser spray 
one-sided

 

Incorrect width setting

 

Undo screws (F, see page 3) and adjust the width setting 

to the left or right 

 

Atomiser drips 

Metering valve incorrectly adjusted 

Check setting, see table 

Atomiser disc faulty/contaminated 

Replace/clean disc 

Atomiser spray discharge 

contaminated 

Clean 

 

 

Atomiser foams 

Residual water in the system 

Completely empty tank, hose and segmental atomiser. 

 

Air in hose 

Hose connection not airtight 

Shorten the hose slightly and fit it on the hose nipple. 

 

 

 

 

 

Clamping bush fixing screw 

Metering pump does not draw 

Metering pump 

Pump carrier 

Metering pump does not draw 

1. Loosen fixing screw 

2. Pull metering pump out 1-2 mm 

3. Tighten fixing screw 

Summary of Contents for MANKAR

Page 1: ...ents and regional regulations for the use of herbicides and if necessary obtain approval from the responsible authorities e g environmental conservation agency Application is to be performed only by a competent user Remarks about usage of the unit Settings This system is not suitable for the application of water Use herbicides for testing the spray action and calibration of the flow rate Usage Pos...

Page 2: ...miser or other small parts Keep pesticide applicators and chemical substances away from children Assembly and preparation for first use Unit assembly is described for the individual models Before using the unit for the first time charge the battery for at least 16 hours Attention Always follow the sequence 1 Insert the plug jack into the charger socket 2 Plug the charging unit into a 230 V mains s...

Page 3: ...re width of the spray hood The optimal spray width under standard operating conditions is set by the manufacturer In the event of deviations the screw F can be loosened in order to move the width adjustment on the atomiser see drawing Further details regarding operating width adjustment can be found on the pages for the individual applicator units Cleaning Do not clean the applicator unit with a h...

Page 4: ... M N O Checking the output volume 1 Place an underlay e g cardboard or paper on the ground and prop up the unit on stands 2 Fill the chemical tank with herbicide undiluted 3 Disconnect the hose from the spray hood and place a measuring cup underneath 4 Open the shut off valve initially setting the metering adjustment knob to the maximum flow rate and simultaneously turning the wheel wait until the...

Page 5: ...round and prop up the unit on stands 2 Fill the chemical tank with herbicide undiluted 3 Disconnect the hose from the spray hood and place a measuring cup underneath 4 Open the shut off valve initially setting the metering adjustment knob to the maximum flow rate and simultaneously turning the wheel wait until the chemical solution is evenly applied 5 Set the chemical solution volume according to ...

Page 6: ... 7 104170 Cable holder plastic Mankar Roll 8 100998 Countersunk Philips head screw M 4 x 12 mm VA 9 100992 Washer M8 Ø8 4 mm VA 10 101145 Allen head screw M 8 x 16 mm VA 11 104140 3 way ball valve Mankar Roll 12 104130 Flow controller mount Mankar Roll 13 104131 Flow controller clips Mankar Roll 14 103319 Flow controller cpl PC HQ PC glass 35 0 mm 15 104100 Frame pump carrier Mankar Roll 16 104150...

Page 7: ... Handle bar bushing Mankar Roll 10 104200 Handle bar guide Mankar Roll 11 104501 Fully suspended drive flange Mankar Roll 12 104502 Friction bearing left Mankar Roll 13 104100 Frame pump carrier Mankar Roll 14 104161 Pump protection ring Mankar Roll 15 104160 Pump protection Mankar Roll 16 104503 Friction bearing right Mankar Roll 17 103477 Wheel 530 x 60 mm pneumatic tyred Mankar Roll 18 104112 A...

Page 8: ... 8 104315 Spring retainer for pressure spring Mankar Roll 9 104314 Pressure spring rotary joint Mankar Roll 10 104316 Bolt Allen key 10 x 130 mm VA Mankar Roll 11 101145 Allen head screw M 8 x 16 mm VA 12 104701 Height adjustment ONE Mankar Roll 13 104731 Width adjustment ONE ONE S Mankar Roll 14 103826 Allen head screw M 6 x 45 mm VA 15 103467 Filister head screw M 6 x 12 mm VA with Allen head 16...

Page 9: ... Mount plastic power pack Mankar Roll ItemPart No Description ItemPart No Description 100527 Metering pump MANKAR 3 capacity 5 12 ml min for MANKAR 110 GP 100492 Metering pump MAFEX 3 capacity 2 20 ml min 1 100528 Pump housing for two channel pump Metering pump MANKAR 1 100493 Pump housing for single channel pump Metering pump MAFEX 2 102209 Rotor 3 chromed brass for piston pump MAFEX MANKAR 2 102...

Page 10: ...spray one sided Incorrect width setting Undo screws F see page 3 and adjust the width setting to the left or right Atomiser drips Metering valve incorrectly adjusted Check setting see table Atomiser disc faulty contaminated Replace clean disc Atomiser spray discharge contaminated Clean Atomiser foams Residual water in the system Completely empty tank hose and segmental atomiser Air in hose Hose co...

Page 11: ...eclare under our sole responsibility that the following products are in conformity with the provisions of the following Council Directive 2006 42 EG Typ MANKAR ONE MANKAR TWO Hiske Weissmann Managing Director Geesthacht January 2020 _______________________ _________________________________ Place and date of signature Name title and signature ...

Reviews: