background image

15.12.2014 

2

 

MANKAR Roll

 

For the undiluted application of Roundup

®

 products (Glyphosate)

 

 

The information on this page applies to all MANKAR Roll units. Details regarding assembly, use and replacement parts are 

provided on the following pages: 

MANKAR-ONE:   Pages 4, 6-9 

MANKAR-TWO:  Pages 5-9 

 

 

Intended usage: 

Weed control in areas of specialised cultivation such as nurseries, orchards and vineyards, ornamental plant and 
vegetable gardens, as well as agricultural, forestry, communal and non-cultivated lands. 

Before application, carefully read the usage instructions for the applicator unit and pesticides. 
Observe safety instructions. 
For questions regarding pesticides, consult the manufacturer. 
Observe the requirements and regional regulations for the use of herbicides. Permission is required from the 
responsible authorities (e.g. environmental conservation agency) for the application of herbicides on surfaces used 
for non-agricultural, forestry or gardening purposes (“non-cultivated lands”). Application is not permitted on sealed 
surfaces (e.g. pavement surfaces) with connection to sewage water systems from which the danger of run-off exists! 
Application may only be carried out by a competent user. 

Noise emission from the unit equates to less than 70 dB (A). 

Precautions

 

Observe the information in the pesticide usage instructions 

regarding user safety, and wear recommended body 

protection. Wear protective gloves when handling the 

chemical solution. 

Do not eat, smoke or drink while working with pesticides. 

Avoid any kind of chemical spillage. Thoroughly wash hands 

and face after completion of work. 

Thoroughly clean and dry the unit immediately after use. Never 

use the mouth to blow out atomiser or other small parts! 

Keep pesticide applicators and chemical substances away from children. 

Assembly and preparation for first use 

Unit assembly is described for the individual models. 

Before using the unit for the first time, charge the battery for at least 16 hours. 

Attention! Always follow the sequence: 

 

1.   Insert the plug jack into the charger socket. 

2.   Plug the charging unit into a 230 V mains socket. 

 

The  battery  has  reached  its  full  voltage  capacity  after  approx.  16  hours'  charging  time.  When  the  charging  process  is 

complete, first unplug the charging unit from the 230 V socket and then remove the unit plug from the charger socket. 
Spray duration when operating one rotating atomiser 

with 1 battery, 6 V - 7 Ah 

approx. 16 hours 

Spray duration when operating two rotating atomisers 

with 1 battery, 6 V - 7 Ah 

approx. 8 hours 

 

The spray width should subsequently be checked - ideally with a piece of cardboard laid out on the ground - and the flow rate 

adjusted (see below for details). 

The battery should be recharged immediately after using the applicator unit. 

 

General information about the function and use of the unit 
Pesticides:

 This applicator unit was originally designed for the undiluted application of Roundup products (Glyphosate). Practical 

experience  has  shown,  however,  that  other  herbicides  can  also  be  used  in  conjunction  with this  technology.  Considering  the 

many  products  on  the  market  with  their  differing  formulas,  it  is  not  possible  to  provide  a  complete  list  with  application  rate 

recommendations. The following information about unit settings relate to Roundup UltraMax (Glyphosate 450 g/L). In general, all 

products  with  a  comparable  viscosity  are  suitable.  If  you  want  to  use  a  product  other  than  Roundup  UltraMax,  its  application 

should be first tested on a small area. Usage instructions for the chosen herbicide must always be observed, along with local 

requirements. 

Summary of Contents for MANKAR

Page 1: ...ents and regional regulations for the use of herbicides and if necessary obtain approval from the responsible authorities e g environmental conservation agency Application is to be performed only by a competent user Remarks about usage of the unit Settings This system is not suitable for the application of water Use herbicides for testing the spray action and calibration of the flow rate Usage Pos...

Page 2: ...miser or other small parts Keep pesticide applicators and chemical substances away from children Assembly and preparation for first use Unit assembly is described for the individual models Before using the unit for the first time charge the battery for at least 16 hours Attention Always follow the sequence 1 Insert the plug jack into the charger socket 2 Plug the charging unit into a 230 V mains s...

Page 3: ...re width of the spray hood The optimal spray width under standard operating conditions is set by the manufacturer In the event of deviations the screw F can be loosened in order to move the width adjustment on the atomiser see drawing Further details regarding operating width adjustment can be found on the pages for the individual applicator units Cleaning Do not clean the applicator unit with a h...

Page 4: ... M N O Checking the output volume 1 Place an underlay e g cardboard or paper on the ground and prop up the unit on stands 2 Fill the chemical tank with herbicide undiluted 3 Disconnect the hose from the spray hood and place a measuring cup underneath 4 Open the shut off valve initially setting the metering adjustment knob to the maximum flow rate and simultaneously turning the wheel wait until the...

Page 5: ...round and prop up the unit on stands 2 Fill the chemical tank with herbicide undiluted 3 Disconnect the hose from the spray hood and place a measuring cup underneath 4 Open the shut off valve initially setting the metering adjustment knob to the maximum flow rate and simultaneously turning the wheel wait until the chemical solution is evenly applied 5 Set the chemical solution volume according to ...

Page 6: ... 7 104170 Cable holder plastic Mankar Roll 8 100998 Countersunk Philips head screw M 4 x 12 mm VA 9 100992 Washer M8 Ø8 4 mm VA 10 101145 Allen head screw M 8 x 16 mm VA 11 104140 3 way ball valve Mankar Roll 12 104130 Flow controller mount Mankar Roll 13 104131 Flow controller clips Mankar Roll 14 103319 Flow controller cpl PC HQ PC glass 35 0 mm 15 104100 Frame pump carrier Mankar Roll 16 104150...

Page 7: ... Handle bar bushing Mankar Roll 10 104200 Handle bar guide Mankar Roll 11 104501 Fully suspended drive flange Mankar Roll 12 104502 Friction bearing left Mankar Roll 13 104100 Frame pump carrier Mankar Roll 14 104161 Pump protection ring Mankar Roll 15 104160 Pump protection Mankar Roll 16 104503 Friction bearing right Mankar Roll 17 103477 Wheel 530 x 60 mm pneumatic tyred Mankar Roll 18 104112 A...

Page 8: ... 8 104315 Spring retainer for pressure spring Mankar Roll 9 104314 Pressure spring rotary joint Mankar Roll 10 104316 Bolt Allen key 10 x 130 mm VA Mankar Roll 11 101145 Allen head screw M 8 x 16 mm VA 12 104701 Height adjustment ONE Mankar Roll 13 104731 Width adjustment ONE ONE S Mankar Roll 14 103826 Allen head screw M 6 x 45 mm VA 15 103467 Filister head screw M 6 x 12 mm VA with Allen head 16...

Page 9: ... Mount plastic power pack Mankar Roll ItemPart No Description ItemPart No Description 100527 Metering pump MANKAR 3 capacity 5 12 ml min for MANKAR 110 GP 100492 Metering pump MAFEX 3 capacity 2 20 ml min 1 100528 Pump housing for two channel pump Metering pump MANKAR 1 100493 Pump housing for single channel pump Metering pump MAFEX 2 102209 Rotor 3 chromed brass for piston pump MAFEX MANKAR 2 102...

Page 10: ...spray one sided Incorrect width setting Undo screws F see page 3 and adjust the width setting to the left or right Atomiser drips Metering valve incorrectly adjusted Check setting see table Atomiser disc faulty contaminated Replace clean disc Atomiser spray discharge contaminated Clean Atomiser foams Residual water in the system Completely empty tank hose and segmental atomiser Air in hose Hose co...

Page 11: ...eclare under our sole responsibility that the following products are in conformity with the provisions of the following Council Directive 2006 42 EG Typ MANKAR ONE MANKAR TWO Hiske Weissmann Managing Director Geesthacht January 2020 _______________________ _________________________________ Place and date of signature Name title and signature ...

Reviews: