background image

15.12.2014 

5

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Assembly 

 

1. 

Mount handle bar guide (A) on frame pump carrier (B). 

2. 

Screw height adjustment (C) on to spray hood (D). 

3. 

Fit height adjustment (C) to frame pump carrier (B) in 

front of or behind wheel. 

4. 

Screw support stand (E) on to frame (in front of or behind 

wheel depending on position of hood). 

5. 

Connect tank from holder (F) to pump intake hose. 

6. 

Connect chemical solution hose from hood (D) to hose 

from frame pump carrier (B) 

7. 

Connect atomiser cables for spray hoods (D) to cable 

harness from frame pump carrier (B). 

8. 

Connect cable harness for frame pump carrier (B) to 

power pack (G) 

 

 

Metering table 
Roundup application rate at 20 °C 

 

Metering 

adjustment 

knob position 

Spray width in cm 

40 

50 

60 

70 

80 

90  100  110 

Litres 

per 

ha 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Checking the output volume 

 

1. 

Place an underlay (e.g. cardboard or paper) on the 

ground and prop up the unit on stands. 

2. 

Fill the chemical tank with herbicide - undiluted. 

3. 

Disconnect the hose from the spray hood and place 

a measuring cup underneath. 

4. 

Open the shut-off valve, initially setting the metering 

adjustment knob to the maximum flow rate and 

simultaneously turning the wheel; wait until the 

chemical solution is evenly applied. 

5. 

Set the chemical solution volume according to the 

output table. 

6. 

Volume calibration: Collect the chemical solution from 

50 wheel revolutions in a measuring cup. If the 

desired volume is not reached, set a larger or a 

smaller volume with the pump metering adjustment 

knob. 

7. 

Perform volume calibration again. 

8. 

Reconnect the hose to the spray hood. 

9. 

The unit is now ready for use. 

 

 

Maximum allowable wheel pressure 2.5 bar 

 

 

 

MANKAR-TWO Flex 

 

Collector receptacle for 

draining the tank contents 

Screw for attaching spray 

hood adjustment 

Screws for presetting spray 

width  

The Allen head screw below the hood 

can be used to adjust the spring 

tension of the rotary joint. 

Summary of Contents for MANKAR

Page 1: ...ents and regional regulations for the use of herbicides and if necessary obtain approval from the responsible authorities e g environmental conservation agency Application is to be performed only by a competent user Remarks about usage of the unit Settings This system is not suitable for the application of water Use herbicides for testing the spray action and calibration of the flow rate Usage Pos...

Page 2: ...miser or other small parts Keep pesticide applicators and chemical substances away from children Assembly and preparation for first use Unit assembly is described for the individual models Before using the unit for the first time charge the battery for at least 16 hours Attention Always follow the sequence 1 Insert the plug jack into the charger socket 2 Plug the charging unit into a 230 V mains s...

Page 3: ...re width of the spray hood The optimal spray width under standard operating conditions is set by the manufacturer In the event of deviations the screw F can be loosened in order to move the width adjustment on the atomiser see drawing Further details regarding operating width adjustment can be found on the pages for the individual applicator units Cleaning Do not clean the applicator unit with a h...

Page 4: ... M N O Checking the output volume 1 Place an underlay e g cardboard or paper on the ground and prop up the unit on stands 2 Fill the chemical tank with herbicide undiluted 3 Disconnect the hose from the spray hood and place a measuring cup underneath 4 Open the shut off valve initially setting the metering adjustment knob to the maximum flow rate and simultaneously turning the wheel wait until the...

Page 5: ...round and prop up the unit on stands 2 Fill the chemical tank with herbicide undiluted 3 Disconnect the hose from the spray hood and place a measuring cup underneath 4 Open the shut off valve initially setting the metering adjustment knob to the maximum flow rate and simultaneously turning the wheel wait until the chemical solution is evenly applied 5 Set the chemical solution volume according to ...

Page 6: ... 7 104170 Cable holder plastic Mankar Roll 8 100998 Countersunk Philips head screw M 4 x 12 mm VA 9 100992 Washer M8 Ø8 4 mm VA 10 101145 Allen head screw M 8 x 16 mm VA 11 104140 3 way ball valve Mankar Roll 12 104130 Flow controller mount Mankar Roll 13 104131 Flow controller clips Mankar Roll 14 103319 Flow controller cpl PC HQ PC glass 35 0 mm 15 104100 Frame pump carrier Mankar Roll 16 104150...

Page 7: ... Handle bar bushing Mankar Roll 10 104200 Handle bar guide Mankar Roll 11 104501 Fully suspended drive flange Mankar Roll 12 104502 Friction bearing left Mankar Roll 13 104100 Frame pump carrier Mankar Roll 14 104161 Pump protection ring Mankar Roll 15 104160 Pump protection Mankar Roll 16 104503 Friction bearing right Mankar Roll 17 103477 Wheel 530 x 60 mm pneumatic tyred Mankar Roll 18 104112 A...

Page 8: ... 8 104315 Spring retainer for pressure spring Mankar Roll 9 104314 Pressure spring rotary joint Mankar Roll 10 104316 Bolt Allen key 10 x 130 mm VA Mankar Roll 11 101145 Allen head screw M 8 x 16 mm VA 12 104701 Height adjustment ONE Mankar Roll 13 104731 Width adjustment ONE ONE S Mankar Roll 14 103826 Allen head screw M 6 x 45 mm VA 15 103467 Filister head screw M 6 x 12 mm VA with Allen head 16...

Page 9: ... Mount plastic power pack Mankar Roll ItemPart No Description ItemPart No Description 100527 Metering pump MANKAR 3 capacity 5 12 ml min for MANKAR 110 GP 100492 Metering pump MAFEX 3 capacity 2 20 ml min 1 100528 Pump housing for two channel pump Metering pump MANKAR 1 100493 Pump housing for single channel pump Metering pump MAFEX 2 102209 Rotor 3 chromed brass for piston pump MAFEX MANKAR 2 102...

Page 10: ...spray one sided Incorrect width setting Undo screws F see page 3 and adjust the width setting to the left or right Atomiser drips Metering valve incorrectly adjusted Check setting see table Atomiser disc faulty contaminated Replace clean disc Atomiser spray discharge contaminated Clean Atomiser foams Residual water in the system Completely empty tank hose and segmental atomiser Air in hose Hose co...

Page 11: ...eclare under our sole responsibility that the following products are in conformity with the provisions of the following Council Directive 2006 42 EG Typ MANKAR ONE MANKAR TWO Hiske Weissmann Managing Director Geesthacht January 2020 _______________________ _________________________________ Place and date of signature Name title and signature ...

Reviews: