Cleaning the Condenser
n
Warning
Disconnect electric power to the ice machine before
performing maintenance on equipment.
AIR-COOLED CONDENSER
A dirty condenser restricts airflow, resulting in excessively
high operating temperatures. This reduces ice production
and shortens component life.
Clean the condenser at least every six months.
1. Remove plastic front grill by removing two Phillips
head screws. Clean grill openings before replacing.
2. Clean the outside of the condenser with a soft brush
or a vacuum with a brush attachment. Clean from top
to bottom, not side to side. Be careful not to bend the
condenser fins.
3. Shine a flashlight through the condenser to check for
dirt between the fins. If dirt remains:
A. Blow compressed air through the condenser fins.
Be careful not to bend the fan blades.
B. If dirt or grease remains between fins, consult
your local service representative.
n
Warning
The condenser fins are sharp. Use care when cleaning
them.
Summary of Contents for UG Series
Page 1: ...Part Number 040006847 12 19 UnderCounter Ice Machines UG Series Technician s Handbook ...
Page 2: ......
Page 12: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 19: ...Part Number 040006847 12 19 19 Model Serial Number Location Model Serial Number Location ...
Page 30: ...PAGE INTENTIONALLY LEFT BLANK 30 Part Number 040006847 12 19 ...
Page 80: ...PAGE INTENTIONALLY LEFT BLANK 80 Part Number 040006847 12 19 ...
Page 92: ...PAGE INTENTIONALLY LEFT BLANK 92 Part Number 040006847 12 19 ...
Page 108: ...108 Part Number 040006847 12 19 PAGE INTENTIONALLY LEFT BLANK ...
Page 125: ......
Page 126: ......
Page 127: ......