22
Part Number: 040006847 12/19
Location of Ice Machine
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
1. The location must be indoors and free from airborne
and other contaminants.
2. The ambient temperature must be higher than 50 °F
(10 °C) and must be lower than 110 °F (43 °C).
3. Water inlet lines - water pressure to the machine
must be above 20 psi (1.38 bar) and below 80 psi
(5.52 bar).
4. The location must not be near heat-generating
equipment or in direct sunlight.
5. The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
6. The location must not obstruct airflow through or
around the ice machine. Refer to the chart below for
clearance recommendations:
Self-Contained Air-Cooled
Top/Sides
8“(203mm)*
Back
5”(127mm)*
*There is no minimum clearance requirement for the top or left and right
sides of the ice machine. The listed values are recommended for efficient
operation and servicing only.
NOTE: The ice machine may be built into a cabinet.
,
Caution
The ice machine must be protected if it will be subjected
to temperatures below 32 °F (0 °C). Failure caused by
exposure to freezing temperatures is not covered by the
warranty. See “Removal from Service/Winterization”.
Summary of Contents for UG Series
Page 1: ...Part Number 040006847 12 19 UnderCounter Ice Machines UG Series Technician s Handbook ...
Page 2: ......
Page 12: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 19: ...Part Number 040006847 12 19 19 Model Serial Number Location Model Serial Number Location ...
Page 30: ...PAGE INTENTIONALLY LEFT BLANK 30 Part Number 040006847 12 19 ...
Page 80: ...PAGE INTENTIONALLY LEFT BLANK 80 Part Number 040006847 12 19 ...
Page 92: ...PAGE INTENTIONALLY LEFT BLANK 92 Part Number 040006847 12 19 ...
Page 108: ...108 Part Number 040006847 12 19 PAGE INTENTIONALLY LEFT BLANK ...
Page 125: ......
Page 126: ......
Page 127: ......