Water Service/Drains
Drinking Water Supply
According to the local water quality, determine whether it
is necessary to install a water treatment system to avoid
the formation of sediment and to filter out impurities and
remove the smell of bleaching powder.
Important
When installing a Manitowoc water filtration system,
be sure to follow the instructions provided with the
filtration system for pipe installation.
Follow these guidelines to install the water inlet lines:
1. Water temperature must be between 50 °F (10 °C)
and 90 °F (32 °C). Be sure all hot water restrictors
installed for other equipment are working (Check
valves on sink faucets, dishwashers, etc.).
2. Water pressure to the machine should be between 20
to 80 psi (140 to 550 kPa).
3. The minimum inner diameter of the pipe is 1/2"
(15 mm).
Drain Connections
• Drain lines must have a 1.5 inch (3.8 cm) drop of run
for each meter (3 feet), and must not create traps.
• The floor drain must be large enough to accommodate
drainage from all drains.
• Run separate bin and water-cooled condenser drain
lines.
• Insulate them to prevent condensation by
temperature.
• Install a tee to vent the ice machine drain to the
atmosphere.
• Appropriate air gaps must be installed for all drain
terminations as per the applicable specifications.
Summary of Contents for UG Series
Page 1: ...Part Number 040006847 12 19 UnderCounter Ice Machines UG Series Technician s Handbook ...
Page 2: ......
Page 12: ...PAGE INTENTIONALLY LEFT BLANK ...
Page 19: ...Part Number 040006847 12 19 19 Model Serial Number Location Model Serial Number Location ...
Page 30: ...PAGE INTENTIONALLY LEFT BLANK 30 Part Number 040006847 12 19 ...
Page 80: ...PAGE INTENTIONALLY LEFT BLANK 80 Part Number 040006847 12 19 ...
Page 92: ...PAGE INTENTIONALLY LEFT BLANK 92 Part Number 040006847 12 19 ...
Page 108: ...108 Part Number 040006847 12 19 PAGE INTENTIONALLY LEFT BLANK ...
Page 125: ......
Page 126: ......
Page 127: ......