ELECTRIC SYSTEM
NBT40 SERVICE MANUAL
3-6
Published 8-01-2017 Control # 287-11
Fuse Box #3
Micro Relay Fuse Box #3
The micro relay fuse block (6, Figure 3-2) is located on the
right side of the fuse relay panel and contains the following
components, Figure 3-5:
•
R1 - Not Used
•
R2 - Not Used
•
R3 - Not Used
•
R4 - Rated Capacity Limiter (RCL) Relay
•
R5 - Crane Power and Remote Power
•
F1 - Spare - 7.5 amp
•
F2 - Hoist Speed Switch - 7.5 amp
•
F3 - Spare - 5 amp
•
F4 - Spare - 10 amp
•
F5 - MWI Lockout Solenoid - 5 amp
•
F6 - Swing Brake Power, Hoist Thumper - 5 amp
•
F7 - RCL Lockout Solenoid - 10 amp
•
F8 - Hoist DRI/MWI Sensor - 3 amp
•
F9 - Spare - 15 amp
•
F10 - Outrigger Power - 15 amp
FIGURE 3-5
7602-2
Reference Only