9
National Crane
Published 8-01-2017 Control # 287-11
9-27
NBT40 SERVICE MANUAL
CRANE INSTALLATION
Hydraulic Pump Connection
The hydraulic system pressure is supplied by a hydraulic
piston pump (1, Figure 9-18) mounted on the truck power
take off (PTO) (8). The pump is driven counter clockwise and
supplies 75 gpm.
For initial pump installation, use the following procedure:
1.
The hydraulic pump has integral mounting flanges and
can be bolted directly to the PTO. Be sure adequate
clearance exists for this type of pump mount.
2.
If the pump is powered through a drive line, a pump
mount must be installed or bolt the pump to an existing
frame cross member.
3.
A mounting bracket needs to be installed so that the rear
mounting bracket on the pump can be secured.
4.
Be sure the drive line is sized to safely carry the
maximum pump horsepower requirements (189 hp
(140.9 kw) at 1800 rpm).
5.
Do not locate the pump more than 42 inches (107 cm)
from the PTO. Do not exceed a 7° drive line angle and
the U-joints on both ends of the drive shaft must be
parallel with each other.
6.
Plan the location of the pump mount and drive line for
adequate clearance between the pump and truck drive
shaft or exhaust system.
7.
Position the pump so that hydraulic lines can be
connected without sharp bends especially the large
suction line from the reservoir.
8.
For drive line installation, install the pump mount to the
truck frame.
9.
Lubricate the splines on the pump shaft and drive
coupling with heavy lithium grease.
10.
If using the configuration shown in Figure 9-18 be sure
to position the case drain port (2) at the highest point
above ground level.
11.
Bolt the pump mounting flange to the PTO or to the
pump mount on the truck.
12.
Torque the mounting flange nuts to 50 ft. lbs (222N
.
m).
13.
Bolt the pump rear mounting bracket to the truck
mounting bracket.
NOTE:
O-ring boss fittings are used for sealing hydraulic
line connections. Make sure the O-ring is in its
groove before tightening.
14.
Remove the dust covers from the pump inlet and outlet
ports and install the hydraulic fittings and lines, see
Figure 9-18.
In Figure 9-18 photo A is from the drivers side; photo B
is from the passengers side.
Crane Rear Maker Lights (Not Shown in Figure 9-17)
Wire #
Truck Function
1403
Rear Red Markers, License
Plate Light
51A
Ground
28
Reverse Light, Back-up
Alarm, O/R Alarm
150
O/R Motion Alarm
CAUTION
Make sure the gate valve on the return line is open before
starting the pump or damage to the pump could result.
FIGURE 9-18
4
1
1
2
3
4
6
5
2
8
7
3
9
1
6
5
A
B
1
7614-1
7614-2
Reference Only
Summary of Contents for National Crane NBT40 Series
Page 1: ...Service Manual National Crane NBT40 Series R e f e r e n c e O n l y ...
Page 2: ...R e f e r e n c e O n l y ...
Page 216: ...SCHEMATICS NBT40 SERVICE MANUAL 10 2 THIS PAGE BLANK R e f e r e n c e O n l y ...
Page 218: ...NBT40 SERVICE MANUAL APL 2 THIS PAGE BLANK R e f e r e n c e O n l y ...
Page 219: ...R e f e r e n c e O n l y ...
Page 220: ...R e f e r e n c e O n l y ...