Part Number 020007115 06/27/2019 27
General Maintenance
This section covers common unit components and their care.
The chart below is an overview of the maintenance that the
end user and service technician should perform, and the
frequency. These figures are the minimum required. If the
condenser is dirty after one week, more frequent cleaning is
recommended. (X = End User, S = Service Company)
NOTE: Cleaning items, other than the nozzle cleaning hoses,
are not supplied with the N2Fusion™ Nitrogen Beverage
Dispenser.
DANGER
It is the responsibility of the equipment owner to perform a
Personal Protective Equipment Hazard Assessment to ensure
adequate protection during maintenance procedures.
DANGER
Failure to disconnect the power at the main power supply
disconnect could result in serious injury or death. The
power switch DOES NOT disconnect all incoming power.
DANGER
Disconnect electric power at the main power disconnect
for all equipment being serviced. Observe correct polarity
of incoming line voltage. Incorrect polarity can lead to
erratic operation.
n
Warning
Never Use Steel Pads, Wire Brushes or Scrapers!
n
Warning
Do not damage the refrigeration circuit when installing,
maintaining or servicing the unit.
n
Warning
Disconnect power to the unit before performing any
service or maintenance functions.
Imprtant
Never use a high-pressure water jet for cleaning or hose
down or flood interior or exterior of units with water. Do
not use power cleaning equipment, steel wool, scrapers
or wire brushes on stainless steel or painted surfaces..
Imprtant
If the machine going to be shutdown for any length
of time it is recommended to go through the Weekly
Cleaning both prior to turning off the unit and when
returned to use.
See "Extended Shutdown Procedure" on
page 32
If the unit is turned off, the product will no longer be kept
cool in the refrigeration cabinet, remove all kegs and keep
refrigerated to prevent spoilage.
Imprtant
When cleaning interior and exterior of unit, care should
be taken to avoid electrical components and wiring. Keep
water and/or cleaning solutions away from these parts.
MANTENANCE SCHEDULE
Maintenance
Daily
Weekly
Mpnthly
After Prplpnged
Shutdpwn
At Start-um
Kegs
X
X
Interior
X
X
X
Gasket
X
X
X
X
Exterior
X
X
X
Drain
X
X
X
Condenser Coil
X
X
X
Casters
X
X
X
Sectipn 4
Maintenance
Summary of Contents for Multiplex N2Fusion
Page 4: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ...34 Part Number 020007115 06 27 2019 Maintenance Section 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 54: ...54 Part Number 020007115 06 27 2019 Charts Section 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 62: ...62 Part Number 020007115 06 27 2019 Diagrams Section 9 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 63: ......