Part Number 020007115 06/27/2019 11
Section 1
General Information
PRODUCT DELIVERY LOCATION
n
Warning
This equipment must be positioned so that the plug is
accessible unless other means for disconnection from
the power supply (e.g., circuit breaker or disconnect
switch) is provided.
n
Warning
Adequate means must be provided to limit the
movement of this appliance without depending on or
transmitting stress to the electrical conduit or gas lines.
n
Warning
To avoid instability the installation area must be capable
of supporting the combined weight of the equipment
and product. Additionally the equipment must be level
side to side and front to back.
n
Warning
This equipment is intended for indoor use only. Do not
install or operate this equipment in outdoor areas.
n
Warning
Do not position the air intake vent near steam or heat
exhaust of another appliance.
The location selected for the equipment must meet the
following criteria. If any of these criteria are not met, select
another location.
• Units are intended for indoor use only.
• The location MUST be level both front to back and side to
side, stable and capable of supporting the weight of the
equipment.
• Position the equipment so it will not tip or slide.
• Recommended air temperature is 41° - 86°F (5° - 30°C), and
must not exceed 90°F (32°C), climate class 4.
• Location must have proper ventilation, DO NOT install in an
enclosure/enclosed cabinet with no access to ambient air.
• The location must not be near heat-generating equipment
or in direct sunlight and must be protected from weather.
• Verify floor of install location is within 1/2” (1.3 cm) of level
front to back, side to side.
• Keep equipment area clear of combustible material.
• Do not install the equipment directly over a drain. Steam
rising up out of the drain will adversely affect operation, air
circulation, and damage electrical /electronic components
• Do not install in an area where a high-pressure water jet
could be used for cleaning.
Clearances
DANGER
Minimum clearance requirements are the same for
noncombustible locations as for combustible locations.
The flooring under the appliance must be made of a
noncombustible material.
DANGER
Risk of fire/shock. All minimum clearances must be
maintained. Do not obstruct vents or openings..
Sides
0" (0 cm)
Back
3” (76mm)
Front
30" (76 cm)
n
Warning
Do not obstruct machine vents or openings this includes
installing in an enclosed cabinet where the unit will not
have access to ambient air.
Heat of Rejection
Model
BTU/hr
ND21TS00
1430 (0.42 kW)
ND21TS01
ND21TS02
ND21TS03
ND21TS04
ND21RS00
ND21RS02
REFRIGERANT CHARGE
Important
Due to continuous improvements, this information is for
reference only. Please refer to the serial number tag to verify..
Model
Type
Refrigerant Charge
ND21TS00
R404A
7.0 oz (198g)
ND21TS01
ND21TS02
ND21TS03
ND21TS04
ND21RS00
ND21RS02
Summary of Contents for Multiplex N2Fusion
Page 4: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ...34 Part Number 020007115 06 27 2019 Maintenance Section 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 54: ...54 Part Number 020007115 06 27 2019 Charts Section 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 62: ...62 Part Number 020007115 06 27 2019 Diagrams Section 9 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 63: ......