Part Number 020007115 06/27/2019 31
Section 4
Maintenance
DALY & WEEKLY CLEANNG
Daily Cleaning
Daily cleaning consists of the following:
• Wiping down the units interior and exterior with an
approved cleaner and sanitizer.
• Checking taps for obstructions and proper flow.
• Cleaning the In-Line Strainer
See "How to Inspect the In-
line Strainer" on page 26
• Drain cleaning
• Pulling unit out and cleaning around the cabinet.
• Manual Keg Cleaning
Sanitizing
Add sanitizer to spray bottle mixed to 400 ppm Quat
concentration and spray all external surfaces. Allow to
remain for 15 minutes, or as directed by manufacturer,
before wiping off.
,
Cautipn
Attention and care should be used to avoid spraying
any electrical component (fans, thermostat and sensor
connections) with any of the fluids.
TAP #1
Surface
TAP #2
Imprtant
TAP #2 Contains an o-ring,
diffuser disc, and diffuser.
NOTE: If removing tap nozzles to clean/sanitize, tap 2
contains a diffuser. DO NOT lose the diffuser and make sure
it is put back on tap 2 after cleaning/sanitizing.
Full daily cleaning steps can be found in the Installation
Operation & Maintenance manual that ships with the unit
(part number 9290312).
Weekly Cleaning
Weekly cleaning consists of the following:
• De-pressurizing the system
• Cleaning the In-Line Strainer
• Mixing approved cleaning & sanitizing solutions
• Keg connectors cleaning & sanitizing
• Using the Prime/Clean button to perform system
cleaning & sanitizing.
Prime/Clean
Button
Cleaning
Keg
Cleaning
Hoses
5 Gallon
Bucket
• Performing Daily Cleaning
Button Illuminations and modes:
• To abort cleaning mode press and hold the cleaning
button until the LED around the Prime/Clean button
turns OFF. This exits cleaning mode into keg change
mode and LED will no longer be illuminated.
Imprtant
If cleaning mode is accidentally aborted or aborted because
of an issue/reason, then the cleaning process will need to
start over from the beginning after a two (2) minute wait.
NOTE: If an error is encountered at any time during cleaning
process the cleaning button will blink ON/OFF rapidly indicating
unit is in an error state and cleaning process has stopped.
To exit error state close both taps then press and hold the
Clean/Prime button until the LED around the button turns OFF
to clear error state and exit into keg change mode.
Once error state is cleared the cleaning process can be started
over after a two (2) minute wait.
NOTE: Priming is required after aborting cleaning or clearing an
error.
See "Priming the System" on page 25
Summary of Contents for Multiplex N2Fusion
Page 4: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ...34 Part Number 020007115 06 27 2019 Maintenance Section 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 54: ...54 Part Number 020007115 06 27 2019 Charts Section 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 62: ...62 Part Number 020007115 06 27 2019 Diagrams Section 9 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 63: ......