Section 2
Installation Instructions
Part Number 5031216
01/09
2-3
Location
The location selected for the beverage dispenser must
meet the following criteria. If any of these criteria are not
met, select another location.
•
The air temperature must be at least 50°F (10°C), but
must not exceed 95°F (35°C).
•
The location must not be near heat-generating
equipment or in direct sunlight and must be protected
from weather.
•
The countertop must be level. Verify that the
countertop can support the weight of the dispenser,
or the dispenser/ice machine combination plus the
weight of the stored ice.
•
Water lines, drains and power outlet must be within 6'
(1.8 m) of location.
Location Requirements for Top Mounted Ice
Machine Installations
Location
— Avoid placing the dispenser and/or ice
machine near heat sources such as radiators, ovens,
refrigeration equipment and direct sunlight.
Clearances
— Refer to the ice machine installation
manual for clearances.
Front of ice machine to be flush with front of
dispenser
— Some ice machines may overhang at the
back of the dispenser.
Drains
— A separate drain line is required for the ice
machine, in addition to a drain line for the ice/beverage
dispenser.
Dispensers may require an adapter kit to install some
top-mounted ice machines. Contact your local distributor
for the correct adapter kit.
For full information about ice machine installation,
including clearances, plumbing lines, connections,
and electrical requirements, see the ice machine
installation manual.
!
Warning
Carbon Dioxide (CO
2
) displaces oxygen. Exposure
to a high concentration of CO
2
gas causes tremors,
which are followed rapidly by loss of consciousness
and suffocation. If a CO
2
gas leak is suspected,
particularly in a small area, immediately ventilate the
area before repairing the leak. CO
2
lines and pumps
must not be installed in an enclosed space. An
enclosed space can be a cooler or small room or
closet. This may include convenience stores with
glass door self serve coolers. If you suspect CO
2
may build up in an area, venting of the B-I-B pumps
and / or CO
2
monitors must be utilized.