9 Diagnostics
eikon e2s Service and Repair Manual UL
99
n/a
Screen
frozen
Touch screen
inoperable
Continual pres-
sure of the touch
screen
Damaged touch
screen / touch
screen depress for
more than 15
seconds.
Display error
message until
touch screen
press released
Error code for recommission test messages
89 Cooling test fail
90 Convection test fail
92 Heater test fail
93 Magnetron test fail
94 Air filter in test fail
95 Air filter out test fail
96 Door closed test fail
97 Door open test fail
98 Incomplete cleaning
Normal error messages
86 On/Off switch operated
99 Air filter override accepted by the customer
100 Main power On, oven connected to the supply door open (for more than 1 minute)
If ‘Door Open’ message is shown while the door is closed, check the Magnetron 230V circuit power
supply.
Error messages (the oven stops operating)
88 Supply voltage error (+/- 10% of rated voltage)
101 Magnetron failed on request
102 Heater ON without request
103 Ambient overheat
104 Magnetron/cavity overheat trip, when oven in idle mode (also see E117)
105 Supply frequency error (+/- 2Hz)
106 Cavity reaches 75°C above set point or 25°C at 275°C
107 Communication error QTS-SRB
108 QTS Personality Module error
109 SRB Personality Module error
110 Incompatible SRB version
111 Cavity sensor failed
112 SRB board sensor failed
113 Magnetron on without request
114 Free – currently not used
115 Convection fan feedback (motor speed controller cable disconnected)
116 Heater OFF on request
117 Magnetron/cavity trip during cook operation cycle (OH-12V gone for > 1sec)
If this OH trip happens in idle mode you get E104.
To reset the error, disconnect the oven from the power supply and re-connect.
Summary of Contents for Merrychef eikon e2s
Page 139: ...12 Replacing components eikon e2s Service and Repair Manual UL 139 View right hand side ...
Page 140: ...12 Replacing components eikon e2s Service and Repair Manual UL 140 View rear side ...
Page 179: ...12 Replacing components eikon e2s Service and Repair Manual UL 179 ...
Page 190: ...13 Circuit boards and diagrams eikon e2s Service and Repair Manual UL 190 ...