10 Tests
eikon e2s Service and Repair Manual UL
111
5.
If the temperature reading is different to the maximum set point,
scroll up to select TEMP. COMP. (Temperature Compensation)
and enter the password.
6.
Enter the figure from the temperature reader on the keypad and
select OK to calibrate the SRB to the temperature sensor (ther-
mocouple).
7.
Retest to check that the cavity temperature reading is the same
as the oven maximum set point temperature.
8.
If the temperature reading is stable repeat the Temperature
Control Test procedure.