5 Installation
eikon e2s Service and Repair Manual UL
54
5.2 Planning the electrical installation
Meaning
It is crucial to the safe and reliable operation of the appliance that the electrical system is installed
carefully and correctly. All the rules and regulations listed here, and the described procedure, must be
strictly followed.
Rules for safe electrical installation of the appliances
Observe the following rules to prevent hazards caused by faulty electrical connections:
The electrical supply must be connected in accordance with applicable local regulations of the
professional associations and of the relevant power supply company.
The case of the appliance must be grounded in a suitable manner.
If two microwave combination ovens are installed in a stacking kit, both cases of the appliances and
the stacking kit itself must be grounded in a suitable manner.
For microwave combination ovens on a wheeled platform, the length of the mains power lead must
accommodate the degree of movement allowed to the appliance by the retaining device on the
wheeled platform. When moving the assembly (platform plus appliance), never place the mains
power lead under tension.
All electrical connections must be checked when the appliance is prepared for first-time use to ensure
cables are laid correctly and connections are made properly.
Equipment provided by customer and electrical installation regulations
The table below shows what equipment must be provided by the customer and what regulations must be
observed when connecting the appliance.
Equipment
Regulations
Fuse
Fuse protection and connection of the appliance must comply with local regulations
and national installation requirements.
Ground fault circuit inter-
rupter (GFCI)
The installation regulations require protection by a ground fault circuit interrupter
(GFCI). Suitable GFCIs meeting the relevant national regulations must be used.
If the installation includes more than one appliance, one GFCI must be provided for
each appliance.
Disconnection device
An easily accessible all-pole disconnection device with a minimum contact separa-
tion of 3 mm must be installed close to the appliance. The appliance must be
connected via this disconnection device.
The disconnection device is used to disconnect the appliance from the electrical
supply for cleaning, repair and installation work.
Summary of Contents for Merrychef eikon e2s
Page 139: ...12 Replacing components eikon e2s Service and Repair Manual UL 139 View right hand side ...
Page 140: ...12 Replacing components eikon e2s Service and Repair Manual UL 140 View rear side ...
Page 179: ...12 Replacing components eikon e2s Service and Repair Manual UL 179 ...
Page 190: ...13 Circuit boards and diagrams eikon e2s Service and Repair Manual UL 190 ...