3-40
REPLACING THE DISTRIBUTOR CONTROL HEAD FILTER
MLT 634 Turbo LSU Série F-E3
MLT 634 -120 LSU Série F-E3
MLT 634 -120 LSU POWERSHIFT Série F-E3
MLT 735 Turbo LSU Série 6-E3
MLT 735 -120 LSU Série 6-E3
MLT 735 -120 LSU POWERSHIFT Série 6-E3
MLT 741 Turbo LSU Série 6-E3
MLT 741 -120 LSU Série 6-E3
MLT 741 -120 LSU POWERSHIFT Série 6-E3
MLT 1035 L Turbo LSU Série 6-E3
- Remove the half clamp 4 (fig. E6/4).
- Undo the two couplings 5 (fig.E6/4) and replace the filter 6 (fig. E6/4).
Be careful to mount the filter 6 (fig. D6/4) in the same direction as the arrow.
- Refit the half clamp 4 (fig. E6/4).
FILLING UP THE OIL
- Clean and refit drain plugs 1 (fig. E6/1) (tightening torque 29 to 39 N.m).
- Fill up with oil (see: 3 - MAINTENANCE: LUBRICANTS AND FUEL) by filler por t 7 (fig.
E6/2).
Use a clean container and funnel and clean the underside of the oil drum before filling.
- Obser ve the oil level on dipstick 8 (fig. E6/5), the oil level should be at the level of the
red point.
- Check for any possible leaks at the drain plugs.
- Replace filler plug 2 (fig. E6/2) with a new filler plug (see: 3 - MAINTENANCE: FILTERS
CARTRIDGES AND BELTS).
HYDRAULIC CIRCUIT DECONTAMINATION
MLT 731 Turbo Série F-E3
- Let the I.C. engine run (accelerator pedal at halfway travel) for 5 minutes without using anything on the lift truck, then for 5 more
minutes while using completely the hydraulic movements (except the steering system and the ser vice brakes).
- Accelerate the I.C. engine at full speed for 1 minute, then activate the steering system and the ser vice brakes.
- This operation makes a pollution abatement of the circuit possible through the hydraulic return oil filter.
MLT 634 Turbo LSU Série F-E3
MLT 634 -120 LSU Série F-E3
MLT 634 -120 LSU POWERSHIFT Série F-E3
MLT 735 Turbo LSU Série 6-E3
MLT 735 -120 LSU Série 6-E3
MLT 735 -120 LSU POWERSHIFT Série 6-E3
MLT 741 Turbo LSU Série 6-E3
MLT 741 -120 LSU Série 6-E3
MLT 741 -120 LSU POWERSHIFT Série 6-E3
MLT 1035 L Turbo LSU Série 6-E3
This should be carried out by your dealer after each oil change.
The hydraulic oil used in the circuit must be at least equal in quality to class 8 (according to NAS 1638). Your dealer will be able
to clean the hydraulic circuit using an external unit and check the quality of the oil in order to ensure the long life of hydraulic
components and par ticularly of the main pump.
E6/5
8
E6/4
5
4
5
6
Summary of Contents for 6-E3 Series
Page 2: ......
Page 4: ......
Page 5: ...1 1 1 OPERATING AND SAFETY INSTRUCTIONS...
Page 6: ...1 2...
Page 32: ...1 28...
Page 33: ...2 1 2 DESCRIPTION...
Page 34: ...2 2...
Page 111: ...2 79...
Page 124: ...2 92...
Page 125: ...3 1 3 MAINTENANCE...
Page 126: ...3 2...
Page 133: ...3 9...
Page 143: ...3 19...
Page 149: ...3 25...
Page 172: ...3 48...
Page 173: ...4 1 4 OPTIONAL ATTACHMENTS FOR USE WITH THE RANGE...
Page 174: ...4 2...
Page 176: ...4 4...
Page 191: ...5 1 5 SPECIFIC AUSTRALIA See also the operator s manual supplement 647065 AU...
Page 192: ...5 2...