39
AWTM 100/2000
AWTM 100/4000
AWTM 125/4000
The thermal output of economizer depends on the heater adjustment and air temperature.
The above data are for correctly adjusted heaters working on natural gas and air temperature of 20°C.
L
N
PE
TP(45°C)
VENT
PE
N
CMSM 3C x 0,75
KR
2
L
Length [mm]
2000
3950
4087
Weight [kg]
14,5
26
47
Power supply [V/Hz]
230/50
Electric input [W]
50
75
Air flow [m
3
/h]
600
750
Thermal output with
HELIOS 10
420 W
950 W
–
Thermal output with
HELIOS 20
690 W
1200 W
–
Thermal output with
HELIOS 30
1400 W
1720 W
–
Thermal output with
HELIOS 40
1900 W
2350 W
–
Thermal output with
HELIOS 50
–
–
2300 W
Available pressure
45 Pa
35 Pa
35 Pa