Economizer is placed in flue system immediately after the tube heater. The position of economizer is
horizontal with slope 2% from the heater. Between heater and economizer, a bend may be inserted if
necessary. For hanging, the economiser is equipped with hanging bolts which can be used for fine
adjustment if its slope. Immediately after economiser, there must be condensate trap with condensate
output and output of flue gases out of the building.
1 HELIOS
tube heater
3 Condensate trap – flue gas-
es measurement here
5 Roof discharge
head
2 Economizer
AWTM
4 Flue duct
6 Condensate outout
connection G3/4"
Min. Slope 2%
2
1
5
4
3
6