1  GENERAL INFORMATION 

The product described in this manual has been built and tested in our production facility. 

All M&C products are packed to be shipped safely. To ensure the safe operation and to maintain the 
safe condition, all instructions and regulations stated in this manual need to be followed. This manual 
includes  all  information  regarding  proper  transportation,  storage,  installation,  operation  and 
maintenance of this product by qualified personnel. 

Please follow all instructions and warnings closely. 

Please  read  this  manual  carefully  before  commissioning  and  operating  the  device.  If  you  have  any 
questions regar

ding the product or the application, please don’t hesitate to contact M&C or your M&C 

authorized distributor. 

 
 
 

2  DECLARATION OF CONFORMITY 

 

  

CE - Certification

 

 

The product described in this instruction manual complies with the following EU directives: 

 
ATEX-Directive  
 

The product described in this manual is produced in accordance with the directive for devices and 
protection systems for appropriate use in hazardous areas 2014/34/EU appendix II.

 

 
EMV-Instruction 

 

 

The requirements of the directive 2014/30/EU 

“Electromagnetic compatibility“ are met. 

 

Low Voltage Directive 

 
The requirement of the directive 2014/35/EU 

“Low Voltage Directive“ are met. 

 

Declaration of conformity  

 
The EU Declaration of conformity can be downloaded from the 

M&C

 homepage or directly requested 

from 

M&C

 

 

Summary of Contents for HEX5.0-1.08

Page 1: ...Regulated Ex Heater HEX5 0 1 08 with internal regulator HEX5 0 2 08 with external regulator II 3 G Instruction Manual Version 1 01 00...

Page 2: ...the application please don t hesitate to contact M C or your M C authorized distributor You will find all the addresses in the appendix of this manual For additional information about our products and...

Page 3: ...14 Cleaning 17 15 Appendix 17 Table of Illustrations Figure 1 Version HEX 5 0 1 08 and Version HEX 5 0 2 08 9 Figure 2 Dimensions of the temperature regulator HEX 5 0 2 08 10 Figure 3 Electrical conne...

Page 4: ...ions and warnings closely Please read this manual carefully before commissioning and operating the device If you have any questions regarding the product or the application please don t hesitate to co...

Page 5: ...all relevant regulations and standards For use in hazardous area observe the relevant national and international instructions and regulations Before connecting the device make sure to compare the sup...

Page 6: ...ctive safety measures are not fulfilled CARE Without the warning triangle means that a material damage may occur in case the respective safety measures are not met ATTENTION This means that an uninten...

Page 7: ...ctions stated in the Type Examination Certificate regarding the installation and operation of the device Only by complying to all requirements stated in the Type Examination Certificate safe operation...

Page 8: ...priately used products and does not cover the consumable parts Please find the complete warranty conditions in our terms and conditions The warranty includes a free of charge repair in our production...

Page 9: ...rammed according to the required temperature class by M C personnel and the device will leave M C protected against unauthorized access The temperature controller is equipped with an over temperature...

Page 10: ...the serial number is located on the top of the temperatur regulator Please refer to this serial number if you have any questions about your device or if you need to order spare parts or consumables 7...

Page 11: ...IP65 EN60529 Ex Protection II 3 G Ex ec nC IIC temperature class T2 to T5 Gc Temperature controller with heater II 3 G Ex ec nC IIC T2 T5 Gc Temperature controller II 3 G Ex ec nC IIC T2 T5 Gc Heater...

Page 12: ...T3 200 392 F 195 383 F 190 374 F 185 365 F 175 347 F 20 S 9611 T3 180 356 F 175 347 F 165 329 F 20 S 9612 T3 165 329 F 160 320 F 150 302 F 20 S 9613 T3 155 311 F 150 302 F 140 284 F 20 S 9614 T3 140...

Page 13: ...rical heater HEX 5 0 2 08 will be delivered separately This temperature controller in its wall mount enclosure needs to be mounted at the selected location and then electrically connected to the termi...

Page 14: ...e Installation of Power Circuits with Nominal Voltages below 1000 V and must be in compliance with all relevant regulations and standards The cables used for connecting the heater must have a diameter...

Page 15: ...check if the housing of the temperature controller and if applicable the connection box HEX 5 0 2 08 are connected to the equipotential bonding Then close lid of the housing and switch on the power s...

Page 16: ...gulated to 180 C 356 F The temperature status alarm signals when the heater reaches the set temperature 12 CLOSING DOWN NOTE The ambient temperature at the device location needs to correspond to the s...

Page 17: ...all relevant regulations and standards Only change the fine wire fuse F1 1 AT 5x20 when the power supply is disconnected DANGER Attention The controller will be programmed according to the required te...

Page 18: ...18 HEX5 0 1 08 HEX5 0 2 08 1 01 00 www mc techgroup com Figure 6 Circuit diagram HEX 5 0 1 08 Values in brackets are for controller 703 Keylock Power N Power PE Power L...

Page 19: ...www mc techgroup com HEX5 0 1 08 HEX5 0 2 08 1 01 00 19 Figure 7 Circuit diagram HEX 5 0 2 08 Power L Power N Power PE Values in brackets are for controller 703 Keylock...

Page 20: ...X5 0 1 08 HEX5 0 2 08 1 01 00 www mc techgroup com Figure 8 Option 2 x PT100 Connection diagrams HEX 5 0 1 08 and HEX 5 0 2 08 Regler Controller HEX5 0 1 08 2x PT100 Regler Controller HEX5 0 2 08 2x P...

Page 21: ...www mc techgroup com HEX5 0 1 08 HEX5 0 2 08 1 01 00 21 Figure 9 Option 2 x PT100 Circuit diagram HEX 5 0 1 08 Power L Keylock Power N Power PE...

Page 22: ...22 HEX5 0 1 08 HEX5 0 2 08 1 01 00 www mc techgroup com Figure 10 Option 2 x PT100 Circuit diagram HEX 5 0 2 08 Keylock Power L Power N Power PE...

Reviews: