16
HEX5.0-1.08, HEX5.0-2.08 | 1.01.00
www.mc-techgroup.com
Figure 5
Example: Heater HEX5.0-1.08 mounted on gas sample probe SP3200
The heater heats-up 1.5 °C per minute (2.7 °F per minute) by default via a programmed temperature
ramp. The total heating-up time is approx. 2 h for example for the gas sample probe SP3200 with
HEX5.0-1/2.08 regulated to 180 °C (356 °F). The temperature status alarm signals, when the heater
reaches the set temperature.
12 CLOSING DOWN
NOTE!
The ambient temperature at the device location needs to correspond
to the stated minimum and maximum ambient temperatures, even
when the unit has been switched off!
13 MAINTENANCE
WARNING!
Before carrying out any type of maintenance work, pay close attention
to the specific system and process safety measures!
DANGER!
Attention ! Explosion hazard!
Do not disconnect the device from the power supply when it is live!