www.mc-techgroup.com
HEX5.0-1.08, HEX5.0-2.08 | 1.01.00
11
8 TECHNICAL DATA
Electrical Heater
Version HEX 5.0-1.08
VersionHEX 5.0-2.08
Temperature regulator
integrated
externally
Part No. 240 V Power
version
20 S 9651
20 S 9656
Part No. 120 V Power
version
20 S 965a
20 S 9656a
Option: connecting box for
heater out of stanles steel
20 S 9630
Power supply
240 V 50 / 60 Hz max. 800 W
or 120 V,50 / 60 Hz max. 830 W
Electr. Connection
Screwed cable gland
Range for cable glands 6 -12 mm
(approx. 0.24”-0.47”),
Teminals; max. 4 mm²
System of protection
IP65 EN60529
Ex Protection
II 3 G Ex ec nC IIC temperature class T2 to T5 Gc
Temperature controller with
heater
II 3 G Ex ec nC IIC T2
– T5 Gc
Temperature controller
II 3 G Ex ec nC IIC T2 - T5 Gc
Heater with terminal box
II 3 G Ex ec IIC T2
– T5 Gc
temperature classes see next page
Ambient temperature
Temperature controller
0 °C to +55 °C
(32 °F to +131 °F)
Temperature controller
0 °C to +55 °C
(32 °F to +131 °F)
Heater terminal box
-20 °C to +70 °C
(~-4 to +158 °F)
Operating temperature
0 °C to max 230 °C (32 °F to max. 446 °F) depending on Temp.-class.
Please specify with order.
Temperature status alarm
10 °C (18 °F) lower than T
SET
Switch capacity 250 V 3 A AC, 0.25 A DC.
1 contact NO, potential-free.
Over temperature limiter
5 °C (9 °F) higher than T
SET
,
manual Reset