24
PROGRAM AND PROGRAM SETTINGS
Programming ability and door control at electrical box are provided by Open/Close/Stop buttons and Select Switch
located on the ECB.
Programs
7.3 PROGRAM SETTING
Door should be in fully closed position while setting one of these following programs
.
PROGRAMS
FUNCTIONS AND DESCRIPTIONS
RUN TIMER
The Run Timer stops automatically the operator after an adjustable time delay either travelling
upwards or downwards. The Run Timer is designed to protect the door and the operator by
preventing the motor over running much longer than the normal time.
MID-STOP
Mid-Stop function will, when active, move the door from the down position to a predetermined
Mid-stop position when the open button or Open/Close device is activated. Once at Mid-Stop,
subsequent Open/close commands will close the door. To move the door to full open position, the
open button must be pressed again.
TIMER TO CLOSE
Timer to Close is a function that, when active, will close the door after an adjustable time delay
once the door has reached its fully open and mid-stop position. The timer to close function works
only in T and TS modes.
TIMER TO CLOSE (from
fully open position only)
Option used in conjunction with MID STOP function. When activated, Timer to Close is active
from the fully open position only and not from the mid-stop position.
ADVANCE CLOSED TIME
This feature, when programmed, allows adjustment of the safety device disabling point and to
determine the final stop point of the door once the “close limit switch” is activated. No “advance
close limit switch” is needed with this feature.
PROGRAM SETTING
PROGRAMS
ACTIVATE
DEACTIVATE
SELECT
SWITCH
RUN TIMER
Check if close limit switch is activated.
Set select switch on D.
Press “Open” button to add 10 sec to the
total time needed to open the door.
Set the select switch on (0,1 or 2)
Set select switch on D.
Press “Stop” button.
MID-STOP
Check the close limit is activated.
Set select switch on “C”
Press “Open” button then press “Stop”
button on desired Mid-Stop position.
Set select switch on “C”
Press “Close” button.
TIMER TO CLOSE
Set select switch on “B”
Press “Open” button to add 15 sec or “Close”
button to add 1 sec each time (max. 4
minutes & 30 seconds)
Set the select switch on T or TS mode
Set select switch on “B”
Press “Stop” button the timer to close is
reset to 0 sec but still activated.
To defeat the timer to close completely
set the switch on desired position (0, 1,
2 or 3)
DEFEATE TIMER
TO CLOSE
(from floor level)
Press the “Stop” four times continuously on
the push button station.
(operator will operate as B2 mode)
Press the “Close” button four times
continuously on the push button station.
(operator return to T or TS mode)
Not required
TIMER TO CLOSE
(from fully open
position only)
Set select switch on ”6”
First press the “Close” button and then the
“Stop”
Set select switch on “6”
Press “Close” button.
*Now the Timer to Close works from fully
open and Mid-Stop position.
ADVANCE CLOSED
TIME
Set the select switch on “7”
Press “Open” to add 50 milliseconds up to
500 milliseconds max.
Press “Close” to deduct 50 milliseconds each
time till it reaches 0/sec.
By pressing “Stop” the default time will
be set to 100 milliseconds.
* LED “INDICAT” comes ON only when time
is increased or reduced. LED OFF when
open or close button is pressed indicates
“Advance Close Time” is reached Maxi or
Mini. (pressing “Stop” LED ON = 100
milliseconds)
The ‘’close limit switch’’ should be readjusted when the ‘’advance closed time’’ is
programmed or deactivated
TIMER
RUN
89
D
B
A
C
E
F 0
7
2
6
5
3
4
1
MID-STOP
D
C
B
A
9
8
F
E
0
3
6
5
7
4
2
1
TIMER TO
CLOSE
D
A
B
C
9
8
F
E
0
4
6
5
7
2
1
3
MID-STOP
TIMER TO
CLOSE
0
F
D
B
C
A
9
8
E
1
6
7
5
2
4
3
0
ADV.
CLOSE
TIME
D
B
C
A
9
8
F
E
5
6
7
2
1
3
4
Summary of Contents for Opera-GH
Page 18: ...18 6 Opera GH exploded view...
Page 29: ...29 7 10 Single phase ECB wiring diagram...
Page 30: ...30 7 11 3 Phase ECB wiring diagram...
Page 42: ...42 9 9 Single phase Hardwired wiring diagram...
Page 43: ...43 9 10 3 phase Hardwired wiring 10 3 phase Hardwired wiring diagram...
Page 45: ...45 NOTES...
Page 46: ...46 NOTES...
Page 47: ...47 NOTES...
Page 48: ...48 BOOK146 REV 1 2007 02 19...