5
1.2
2 to 5 HP
SUPPLY VOLTAGE...............................208, 460, 575 V
AC
three-phase
CONTROL VOLTAGE............................24 V
AC
class 2 transformer, 2 amp fuse type ACG
MOTOR.................................................Continuous duty 2, 3, 5 horsepower
OPERATOR OUTPUT SPEED..............43 RPM
NET WEIGHT (Operator only)...............137 Lbs (62 Kg)
STANDARD WIRING TYPE..................C2 (momentary contact to open/stop and constant-pressure-to-close)
APPLICATION.......................................Very heavy duty worm gear for sectional doors, rolling doors and grilles
DUTY.....................................................25 cycles/hour or >80 cycles/day
Table 2 - Operator Selection Guide 2 to 5 HP
Maximum Area in Square Feet (general guideline)
Rolling Doors
Sectional Doors
HP
Insulated
Steel
16 ga
Steel
Steel Grilles
20 ga
Steel
Alu. Door
22 ga Steel
Alu. Grilles
24 ga
Steel
Steel
18 ga
ins.
Steel
18 ga
20 ga
ins.
Wood
Steel 20 ga,
22 & 24 ga
ins.
Alu. Steel
22 & 24 ga
Fiber
Glass
2
451
613
660
560
620
660
3
620
830
890
830
870
910
5
*
*
*
*
*
*
* Consult Factory
For technical support, please call
1-800-361-2260
for more information
Figure 2 - MGH Dimensions 2 to 5 HP