28
8.3
Radio Control Functions – 1 and 3-Button Transmitters
Table 7 - Radio Control Functions - 1-Button Transmitter RADIOEM101
Transmitter
Modes
Functions
Programming
(On operator's ECB)
1-Button
Transmitter
RADIOEM101
Commercial
Sequence -
1-Button
OPEN / CLOSE → Button
Door is CLOSED:
- Click Button → Door OPENS
FULLY
During UPWARD Travel:
- Click Button → Nothing happens
Door is OPENED:
- Click Button → Door CLOSES
FULLY
During DOWNWARD Travel:
- Click Button → Door reverses and
OPENS FULLY
Door is STOPPED:
- Not possible in this mode. Door is
either FULLY OPENED or FULLY
CLOSED.
Standard default mode.
1.Door is in fully CLOSED position.
2.On ECB, verify if the close limit switch is
activated (CLOSE LED is ON).
3.On ECB, set select switch on
9 = SBC
.
4.On ECB, press “
STOP
” button.
5.On ECB, select run mode
(1, 4, or 5)
.
Single Button
Control (SBC)
Available with
the Electronic
Control Board
(ECB) only.
Alternating
Sequence
OPEN / STOP / CLOSE → Button
Door is CLOSED:
- Click Button → Door OPENS
During UPWARD Travel:
- Click Button → Door STOPS
Door is STOPPED:
- Click Button → Door CLOSES
During DOWNWARD Travel:
- Click Button → Door STOPS
Door is STOPPED:
- Click Button → Door OPENS
Note
: If the door is STOPPED for
more than 2 minutes, the next
movement will be UPWARD
regardless of the previous
movement.
1.Door is in fully CLOSED position.
2.On ECB, verify if the close limit switch is
activated (CLOSE LED is ON).
3.On ECB, set select switch on
9 = SBC
.
4.On ECB, press “
OPEN
” button.
5.On ECB, select run mode
(1, 4, or 5)
.
For technical support, please call
1-800-361-2260
for more information