0.07
3
F12R L.C. 50 cc.
Signalling System
B
Chapter
ISSUe
paGe
If right or left turn indicators are not working, check:
1) CONtINUItY OF LIGht BULB aND reLatIVe COUpLING
) VOLtaGe DeLIVereD tO rIGht Or LeFt LaMp SOCKet
1. continuity of light bulb and relative coupling
- remove light bulb.
- Connect
Tester (
Ω
)
to light bulb.
- Check continuity of light bulb.
- Not compliant:
replace light bulb.
See “Checking switches” on page 11
2. Voltage delivered to right or left lamp socket
- Connect
Tester (20 V dc)
to connector of light bulb coupling, as follows:
- Left turn indicator
(a)
:
- terminal (+) of tester
purple cable
(1)
.
- terminal (-) of tester
Chassis grounding
(2)
.
- right turn indicator
(B)
:
- terminal (+) of tester
Green cable
(3)
.
- terminal (-) of tester
Chassis grounding
(4)
.
- turn key
“ON”.
- Operate switch to activate left turn indicators
(a)
- Operate switch to activate right turn indicators
(B)
- Voltage delivered to lamp socket:
> 12 V.
- Not compliant:
resume connection between switch of turn indicators and connector of light bulb coupling.
See “Wiring Diagram”.
F. 41a
4
3
1
F. 41b
N
VL
10
W
N
VR
10
W
2
a
B
Tester (dc 20 V)
Tester (dc 20 V)