27
CODE ON DISPLAY
H1
H2
H3
H4
H5
H6
EXPLANATION
Central Heating Sensor Error
DHW Sensor Error
Central Heating Circuit Low Water Pressure Error
High Temperature Measurement Error >= 95°C
Limit Thermostat Error
Main Heat Exchanger Water Level Error
C. DIGITAL SCREEN
Shows operating parameters and errors occuring during operation with the warning
codes on the screen.
a
b
c
a) Heating Capacity Indicators: Shows which heating elements are in operation, indicating
the modulation level of the boiler.
b) Heating Mode Indicator: The dash position on the display shows whether the boiler is
operating in heating or in DHW supply mode.
c) Digital Units: Adjusted temperature, current boiler temperature and error codes are
shown in this section of the display.
5.2 ERROR CODES
Summary of Contents for OMEGA
Page 1: ...rev no 02 23 08 2019...
Page 16: ...13...
Page 31: ...28 5 3 TROUBLESHOOTING...
Page 34: ...31 7 TECHNICAL TABLE...
Page 39: ...10 3 RELAY BOARD GROUP DETAIL 36 66 67 68 69 70 71 72...
Page 42: ...11 1 MAIN HEAT EXCHANGER GROUP DETAIL 39 31 32 34 33 35 36 37 42 43 44 46 38 39 40 41 45...
Page 43: ...11 2 RELAY BOARD GROUP DETAIL 40 47 48 49 50 51 52 53 54...