3.10 ROOM THERMOSTAT CONNECTION
An electric terminal is left outside the control panel plastic box so that the control panel
is not opened while connecting an optional room thermostat. You can see this terminal
in the below picture. Remove the jumper cable and connect the room thermostat volt
free cables.
&
WARNING!
•
Do not connect any voltage to this therminal as this will damage the boiler and in
validate the warranty.
•
In cases where a wireless room thermostat requires a line (220V) connection, a
seperate electricty cable must be connected to the thermostat. Do not make a
connection from the boiler's electricty supply. This may damage the boiler and
invslidate the warranty.