The cable connections are clearly marked on the cables to be connected to the RCD device.
•
Monophase L N
•
3-phase
R S T N
•
Earth connection is marked with
•
Make sure that the energy cables are fixed tightly (with 2.8 -3.5 Nm
torque) onto the RCD device. Loose connections may generate sparks
and may cause fire risk.
•
Do not operate the boiler without proper earth connection. Fix a proper
size earth cable tightly to the ring cable clip and tighten the screw to
the boiler chassis.
•
Use the cable glands provided on the boiler to secure the energy and
earth cables.
&
WARNING
19
N T S R
Blue
50-100kW