Strona
23
z
26
4.3.5. Factory (default) programs for washing segment.
The controller contains 4 factory programs, which are shown in the following tables.
The remaining 4 programs are empty.
the signs used in the following tables:
the markings used in the following tables:
CW
hot water relay
ZZ
dump valve relay
ZW
cold water relay
PMY washing relay
PP
vacuum pump relay
PM
washing pump relay
PML
milk pump relay
PPR
stirrer relay
H
hydrostatic
PROGRAM NO. 1
No. of LED diode
1
2
3
4
5
6
7 8
comments
No. of relay
1
2
3
4
5
6
7
H
No. of
step
step
duration
CW ZW PP PML ZZ PMY
1
15:00
0
1
0
0
0
1
0 1 max. time
2
03:00
0
0
1
0
0
1
0 0
3
00:30
0
0
1
1
0
1
0 0
4
15:00
1
0
0
0
1
1
0 1 max. time
5
07:30
0
0
1
0
1
1
0 0
6
03:30
0
0
1
0
0
1
0 0
7
00:30
0
0
1
1
0
1
0 0
8
15:00
0
1
0
0
0
1
0 1 max. time
9
05:00
0
0
1
0
0
1
0 0
10
00:30
0
0
1
1
0
1
0 0
01:05:30 maximum total time
PROGRAM NO. 2
No. of LED diode
1
2
3
4
5
6
7 8
comments
No. of relay
1
2
3
4
5
6
7
H
No. of
step
step
duration
CW ZW PP PML ZZ PMY
1
15:00
0
1
0
0
0
1
0 1
2
04:00
0
0
1
0
0
1
0 0
3
00:30
0
0
1
1
0
1
0 0
4
15:00
1
0
0
0
1
1
0 1
5
11:30
0
0
1
0
1
1
0 0
6
02:30
0
0
1
0
0
1
0 0
7
00:30
0
0
1
1
0
1
0 0
8
15:00
0
1
0
0
0
1
0 1
9
06:00
0
0
1
0
0
1
0 0
10
00:30
0
0
1
1
0
1
0 0
01:10:30 maximum total time