background image

 

 

 

Misprints and printing errors reserved 

responsible for reporting any transport damage to the 
transporter and/or Ma-koi within 24 hours. The untimely 
checking and reporting of transport damage may lead to 
expiry of the warranty. 

 

2.4 

Ma-koi is not responsible for the consequences of incorrect 
application, the use, maintenance and/or operation of the 
product by the customer, nor for normal wear. This applies 
to consequences of thermal, chemical, electro-chemical or 
electrical influences in particular, as also for failure to 
observe our user guide. The same applies for damage as a 
consequence of modifications or adjustments to the 
product which were not approved by Ma-koi in advance. 

2.5 

Damage that can be unambiguously attributed to incorrect 
usage of the product, is the responsibility of and for the 
account of the user. In case of returning of the product, 
the customer shall ensure proper packing and shipment 
free of breakage/damage. The customer himself is 
responsible for damage caused by inadequate packaging. 

2.6 

Claims against Ma-koi become barred within a year after 
delivery of the goods to the customer. The same applies to 
a claim for damage, regardless the legal cause. The period 
of limitation does not apply in case of concealment of 
damages, physical injury and other damage as a 
consequence of intent or deliberate negligence. 

2.7 

If, during the investigation of the reported damage or 
during the repair of the failure/defect by us, it appears 
that the reported damage or claims were intentional or a 
result of negligence, we can charge a fee for the removal 
of the defects. The customer has the right to refuse a 
necessary repair and demand the return of the filter. In 
principle, every investigation is bound to a lump-sum 
indemnity if the customer himself is responsible for the 
damage. 

2.8 Replacement parts 

The replacement parts will be available for a period of 5 
years after the delivery of the product. Prices apply, as set 
out on the website of Ma-koi. 
 

2.9 Reservation of changes 

The manufacturer reserves the right to modify the product 
at all times without prior notification. No claims can be 
made if, e.g. the design, the functionality or performance 
of the filter is subject to modification. The specifications of 
the filter offer will prevail and are guaranteed. 

 

 

 

3. GENERAL 

 

3.1 Description of the drum filter  

The Bio-drum and/or the drum filter consists of a drum 
sieve that is driven by an electro-motor. Additionally, 
control electronics and a rinse pump are included.

 

The

 

drum filter serves to filter and discharge floating particles, 
dirt particles and algal remains. Regarding the Bio-drum 
there is an additional space, fitted with an air stone or air 
disc, in which the organic filter material Helix can be 
placed. 

This drum filter is a product that may be applied only in 
fresh water. The filter was designed for use in ponds.  

The water to be filtered flows (due to gravity or pumping) 
into the inlet openings of the drum. On the inside of the 
drum, dirt will remain behind as a result of the mesh that 
was fitted across the drum. As the cloth gets more 
polluted, less water will flow through the drum. The water 
level behind the drum will fall (in case of a gravity 
installation) and a sensor present there, measuring the 
water level, will subsequently activate the electronics. The 
electronics will send a signal to the motor of the drum and 
to the rinse pump. The drum will rotate, while the rinse 
pump will, under high pressure, control the nozzles that 
spray the mesh in the rotating drum clean. The waste 
water is collected by a duct in the drum and will flow 
outside, via the duct, for instance into the sewer. After the 
set rinsing time has elapsed (14 seconds as standard), the 
electronics will be deactivated again. The drum will stop 
rotating and the pump will stop spraying water towards 
the nozzles. 

3.2 Warning 

Only staff sufficiently knowledgeable about drum filters is 
permitted to perform maintenance/activities on this 
equipment. This staff must be familiar with the 
international regulations for accident prevention. 
Connection and settings must be in conformity with the 
applicable electrical regulations. 

 

 3.3 Used symbols and warnings 

WARNING 

 ELECTRICAL DANGER!  

LIFE-THREATENING! 

Electric shocks may lead to death or 
serious physical injury for personnel, or 
damage to the equipment. Ensure that 
unauthorised persons are not able to get 
access or may come in contact with the 
device. Disconnect the device from the 
power supply before you start working on 
it. Do not put the filter in use if the 
power supply has not been correctly 
connected to the (protective) earth.  

Summary of Contents for Bio100

Page 1: ...1 Misprints and printing errors reserved INSTALLATION AND USER GUIDE FOR MAKOI DRUM FILTERS AND BIODRUMS Scan the QR code for even more information ...

Page 2: ... 5 7 Commissioning of the filter 6 7 1 Positioning the filter 6 7 2 Connecting gravity 6 7 2 1 Setting of sensor float 7 7 2 3 Connecting rinse pump 7 7 2 4 Connecting motor drum filter 8 7 2 5 Coil frequency 8 7 2 6 Control electronics 9 7 2 7 Control electronics for Drum 100 and Bio drum 200 with flushing channel connection 10 7 3 Connecting pump fed system 10 7 3 1 Installation of float 10 7 3 ...

Page 3: ...ith regard to the usage and the suitability for an application will be accepted only if they fall within the Ma koi specifications specified in writing as for instance stated in this manual Any other verbal agreements for instance during preparatory discussions advertisement etc in relation to the product are valid only in case what was pledged is an integral part of a written agreement Only the t...

Page 4: ...bject to modification The specifications of the filter offer will prevail and are guaranteed 3 GENERAL 3 1 Description of the drum filter The Bio drum and or the drum filter consists of a drum sieve that is driven by an electro motor Additionally control electronics and a rinse pump are included The drum filter serves to filter and discharge floating particles dirt particles and algal remains Rega...

Page 5: ...h a maximum residual current of 30 mA DIN VDE 0100T739 Use the device only when connected to a correctly installed socket Keep the plug and the wiring dry Ensure that the cables are protected to prevent damage and consequential short circuit THE ELECTRICAL WIRING AND OR PLUGS MAY NOT BE CUT THROUGH DOING THIS WILL CAUSE THE MANUFACTURER S WARRANTY TO EXPIRE IMMEDIATELY Only use cables installation...

Page 6: ...cs contains switching components and must be placed in an interference free room Certain pumps or UV units may adversely affect the functioning of the electronics In case of frost the filter must be protected against freezing If the filter is being activated outdoors all pipes must be empty If the filter remains operative the pipes for the rinse water must be protected against freezing Damage as a...

Page 7: ...ged This is indicated on the display Siemens Logo in the Electronics Cabinet 7 2 1 Setting for sensor float Upon delivery the sensor has already been installed for use as gravity and in such a way that it will function properly in most situations Still you will need to check on proper functioning after installation and adjust the float in the best way possible If the float is in lowest position 4 ...

Page 8: ... frequency Make sure that the coil frequency is not too high If the drum is installed in an existing system the coil frequency will be high over the first days weeks because the pond is being cleaned In case of warm weather the coil frequency will be higher more feed and more algae growth than in case of colder weather Other causes of a too high coil frequency are a pond pump that is too large too...

Page 9: ...ing the parameters is done at own risk in case the power supply is connected Take care of electrical hazard when opening The control cabinet must be connected to an approved earthed socket The electronics must be installed vertically The electronics may not be assembled unprotected during rain Per connected side a maximum of 660 W of auxiliary equipment may be connected Functions of the green butt...

Page 10: ...float upside down for the drum section at the inlet 1st chamber Please note The float must be installed in reverse because here the circuit is to work reversely And the upper blue caps must be removed If the water rises for the drum filter it becomes polluted and the rinse cycle must be activated If in the reversed situation the float goes up and stays up the system should deactivate after 30 seco...

Page 11: ...ance and cleaning The filters are low maintenance However maintenance and inspection tasks below are required for proper functioning Check the correct functioning of the float every month Perform a manual rinse every month and check whether the nozzles perform good spraying A nozzle may get clogged or calcified Also the rinse pump may perform less pressure Clean the nozzles if necessary Clean the ...