background image

 

 

 

Misprints and printing errors reserved 

So pay attention to the following, with regard to a 
maximum flow per pipe: 

The pond water level should not fall too much. If the pond 
water level falls by 1 cm, the flow per tube may fall by as 
much as 1 to 2 m3/hour. In case of large fluctuations of 
the pond water level (due to evaporation, replenishing or if 
you rinse the filter) there is a risk of insufficient water 
being supplied to the filter. If your pump pumps more 
water than arrives into the filter, the drum will be pumped 
empty and the sensor will appear above the water level, 
which will cause the filter to go in rinse cycle.  

If the supply pipes are of significant length, with many 
bends, there will be lots of friction loss and a lot less than 
10 m3/hour may be supplied per pipe. 

Entries that are not used should be sealed. 

Discharge of dirt: 
The dirt will be sprayed through the nozzles of the mesh, 
into the flushing channel. The flushing channel can be 
connected directly to the sewer or to a drainage point. 

Return to pond: 
The pomp is connected to the 110 mm discharge. If 
necessary, make use of a flexible coupling, for a good 
transit to your pump. A flexible connection will also reduce 
vibrations. 

Make sure that you never apply a pump larger than 
recommended for the filter. As you go towards the 
maximum of the filter in terms of the selected pump, you 
should ensure that sufficient water is supplied and that the 
dry running function of the electronics is engaged. This is 
indicated on the display Siemens Logo in the Electronics 
Cabinet. 

7.2.1 Setting for sensor/float 

Upon delivery, the sensor has already been installed for 
use as gravity and in such a way that it will function 
properly in most situations. Still you will need to check on 
proper functioning after installation and adjust the float in 
the best way possible. 

  

 

 

If the float is in lowest position (4), the filter will postpone 
the rinsing function, creating more pressure in the drum 
(not recommended), although in case of a calamity or too 
little water supply from the soil drains, this could be a 
temporary solution, so the filter can keep running. If the 
float is in highest position (image 3) the filter will rinse 
more quickly and more often. Image 1 represent the 

‘normal’ 

position, recommended for most ponds. 

The cables of the float must be connected to numbers 1 
and 2 in the electronics box. The wires of the magnet 
contact must be connected to numbers 3 and 4. 

7.2.3. Connecting the rinse pump 

The Rinse pump is included with the Ma-koi drum filters 
and Bio-drums, as standard. In case of the Bio-drum 30, a 
connection has already been installed for the suction side 
of the rinse pump. 

 

 

 

 

 
 
 
 
For the other types, you can use one of the 110 mm exits, 
by applying an adapter (ring) towards 32 or 25 mm for the 
rinse pump. Or create a transit yourself at the location of 
your choice, using a 25 or 32 mm tank transit. Make sure 

that you assemble this transit into the ‘clean’ side of the 

filter and not into the first chamber where the dirt enters. 
This is to prevent clogging of the spray nozzles. 

 

3

: Normal position (recommended)

 

4: Lowest position 

5: Highest position 

6:witlof tank 
transit 

Summary of Contents for Bio100

Page 1: ...1 Misprints and printing errors reserved INSTALLATION AND USER GUIDE FOR MAKOI DRUM FILTERS AND BIODRUMS Scan the QR code for even more information ...

Page 2: ... 5 7 Commissioning of the filter 6 7 1 Positioning the filter 6 7 2 Connecting gravity 6 7 2 1 Setting of sensor float 7 7 2 3 Connecting rinse pump 7 7 2 4 Connecting motor drum filter 8 7 2 5 Coil frequency 8 7 2 6 Control electronics 9 7 2 7 Control electronics for Drum 100 and Bio drum 200 with flushing channel connection 10 7 3 Connecting pump fed system 10 7 3 1 Installation of float 10 7 3 ...

Page 3: ...ith regard to the usage and the suitability for an application will be accepted only if they fall within the Ma koi specifications specified in writing as for instance stated in this manual Any other verbal agreements for instance during preparatory discussions advertisement etc in relation to the product are valid only in case what was pledged is an integral part of a written agreement Only the t...

Page 4: ...bject to modification The specifications of the filter offer will prevail and are guaranteed 3 GENERAL 3 1 Description of the drum filter The Bio drum and or the drum filter consists of a drum sieve that is driven by an electro motor Additionally control electronics and a rinse pump are included The drum filter serves to filter and discharge floating particles dirt particles and algal remains Rega...

Page 5: ...h a maximum residual current of 30 mA DIN VDE 0100T739 Use the device only when connected to a correctly installed socket Keep the plug and the wiring dry Ensure that the cables are protected to prevent damage and consequential short circuit THE ELECTRICAL WIRING AND OR PLUGS MAY NOT BE CUT THROUGH DOING THIS WILL CAUSE THE MANUFACTURER S WARRANTY TO EXPIRE IMMEDIATELY Only use cables installation...

Page 6: ...cs contains switching components and must be placed in an interference free room Certain pumps or UV units may adversely affect the functioning of the electronics In case of frost the filter must be protected against freezing If the filter is being activated outdoors all pipes must be empty If the filter remains operative the pipes for the rinse water must be protected against freezing Damage as a...

Page 7: ...ged This is indicated on the display Siemens Logo in the Electronics Cabinet 7 2 1 Setting for sensor float Upon delivery the sensor has already been installed for use as gravity and in such a way that it will function properly in most situations Still you will need to check on proper functioning after installation and adjust the float in the best way possible If the float is in lowest position 4 ...

Page 8: ... frequency Make sure that the coil frequency is not too high If the drum is installed in an existing system the coil frequency will be high over the first days weeks because the pond is being cleaned In case of warm weather the coil frequency will be higher more feed and more algae growth than in case of colder weather Other causes of a too high coil frequency are a pond pump that is too large too...

Page 9: ...ing the parameters is done at own risk in case the power supply is connected Take care of electrical hazard when opening The control cabinet must be connected to an approved earthed socket The electronics must be installed vertically The electronics may not be assembled unprotected during rain Per connected side a maximum of 660 W of auxiliary equipment may be connected Functions of the green butt...

Page 10: ...float upside down for the drum section at the inlet 1st chamber Please note The float must be installed in reverse because here the circuit is to work reversely And the upper blue caps must be removed If the water rises for the drum filter it becomes polluted and the rinse cycle must be activated If in the reversed situation the float goes up and stays up the system should deactivate after 30 seco...

Page 11: ...ance and cleaning The filters are low maintenance However maintenance and inspection tasks below are required for proper functioning Check the correct functioning of the float every month Perform a manual rinse every month and check whether the nozzles perform good spraying A nozzle may get clogged or calcified Also the rinse pump may perform less pressure Clean the nozzles if necessary Clean the ...

Reviews: