background image

 

 

 

11 

Misprints and printing errors reserved 

If the float is in the lowest position, the system is stand-
by. If the float is in highest position (float is floating) then 
the process will commence (drum will start rotating and 
the rinse pump will spray-clean the cloth). This will last for 
14 seconds (standard value). 

If the float remains in the  from the filter. The drum will 
rinse for 30 seconds (standard value) and the electronics 
will switch to dry-running protection.

 

7.3.2 Connection of return to pond 

The return after the filter should first go up to determine 
the desired height inside the filter. It should not be too 
low, in connection with the bio-filter material present. 
Neither should it be too high, because this will lead to a 
high coil frequency of the filter. Also here it applies that 
the drum should be adjusted during operation. A rinse 
cycle must be started when the water level difference 
before and after the drum is approx. 10-15 cm. Make sure 
that the vertical section remains open to prevent tilting 
action, causing the drum filter to be pumped dry. 

If you wish to pump more water than 1x 110 mm pipe can 
handle concerning the gravity, you must create additional 
transits. You can also connect the return to the pond by 
use of a wider diameter pipe.

 

 

 

 

 

 

 

 

 

 

Please note: 

That in terms of Bio-drums, the water in the last chamber 
(biological chamber) is at least 15 cm lower than in image 
2. So this is just before your drum filter will rinse. 

 
 

8. Maintenance and cleaning 

The filters are low maintenance. However, maintenance- 
and inspection tasks below are required for proper 
functioning: 

 

Check the correct functioning of the float every 
month. 

 

Perform a manual rinse every month and check 
whether the nozzles perform good spraying. A 
nozzle may get clogged or calcified. Also, the rinse 
pump may perform less pressure. Clean the 
nozzles if necessary. 

 

Clean the sieve element with a strong acid 
(hydrochloric acid 30-35%). After a while, biofilm 
and calcium deposits may arise, as a result of 
which the rinse frequency will strongly increase. 
Observe the safety regulations during cleaning by 
use of acids. Wear protective clothing and safety 
goggles. 

9. Technical specifications 

Rinse pump: Oase ProMax Garden Classic 3000 
pressure: 4.1 bar. 

 

P: 600 W 
Qmax: 3,000 l/u 
U: 220-230 V 
 
Mesh size sieve: 60 micron 

Electronics:  

Siemens Logo8 

  

  

IP54 

  

  

Max. capacity per side: 800 W 

  

  

Voltage: 220 V/50-60 Hz 

 

10. Declaration of distributor 

In addition to what is set out in this manual, the general 
terms of Ma-koi B.V. apply for any claims against Ma-koi 
with regard to the products in this manual. 

Specifications may vary as a consequence of technical 
improvements. 

Should this filter in some way not meet the requirements 
you would expect from Ma-koi, then contact the dealer 
where you purchased the filter or contact Ma-koi directly. 

2 years of product warranty and/or 150,000 rinses 

10.1 Distributor 

Ma-koi Swimming Jewels V.o.f. 
Duurzaamheidstraat 19 
8094SC Hattemerbroek 
Nederland 
 
Tel: +31384447366 

[email protected]

 

www.makoi.nl

 

 

Maximum 

 

 

Bio30: 53 cm   

Drum 30: 20 cm 

Bio40: 53 cm   

Drum 50: 40 cm 

Bio50: 70 cm   

Drum 100: 40 cm 

Bio100: 70 cm   

 

Bio200: 65 cm 

 

 

Summary of Contents for Bio100

Page 1: ...1 Misprints and printing errors reserved INSTALLATION AND USER GUIDE FOR MAKOI DRUM FILTERS AND BIODRUMS Scan the QR code for even more information ...

Page 2: ... 5 7 Commissioning of the filter 6 7 1 Positioning the filter 6 7 2 Connecting gravity 6 7 2 1 Setting of sensor float 7 7 2 3 Connecting rinse pump 7 7 2 4 Connecting motor drum filter 8 7 2 5 Coil frequency 8 7 2 6 Control electronics 9 7 2 7 Control electronics for Drum 100 and Bio drum 200 with flushing channel connection 10 7 3 Connecting pump fed system 10 7 3 1 Installation of float 10 7 3 ...

Page 3: ...ith regard to the usage and the suitability for an application will be accepted only if they fall within the Ma koi specifications specified in writing as for instance stated in this manual Any other verbal agreements for instance during preparatory discussions advertisement etc in relation to the product are valid only in case what was pledged is an integral part of a written agreement Only the t...

Page 4: ...bject to modification The specifications of the filter offer will prevail and are guaranteed 3 GENERAL 3 1 Description of the drum filter The Bio drum and or the drum filter consists of a drum sieve that is driven by an electro motor Additionally control electronics and a rinse pump are included The drum filter serves to filter and discharge floating particles dirt particles and algal remains Rega...

Page 5: ...h a maximum residual current of 30 mA DIN VDE 0100T739 Use the device only when connected to a correctly installed socket Keep the plug and the wiring dry Ensure that the cables are protected to prevent damage and consequential short circuit THE ELECTRICAL WIRING AND OR PLUGS MAY NOT BE CUT THROUGH DOING THIS WILL CAUSE THE MANUFACTURER S WARRANTY TO EXPIRE IMMEDIATELY Only use cables installation...

Page 6: ...cs contains switching components and must be placed in an interference free room Certain pumps or UV units may adversely affect the functioning of the electronics In case of frost the filter must be protected against freezing If the filter is being activated outdoors all pipes must be empty If the filter remains operative the pipes for the rinse water must be protected against freezing Damage as a...

Page 7: ...ged This is indicated on the display Siemens Logo in the Electronics Cabinet 7 2 1 Setting for sensor float Upon delivery the sensor has already been installed for use as gravity and in such a way that it will function properly in most situations Still you will need to check on proper functioning after installation and adjust the float in the best way possible If the float is in lowest position 4 ...

Page 8: ... frequency Make sure that the coil frequency is not too high If the drum is installed in an existing system the coil frequency will be high over the first days weeks because the pond is being cleaned In case of warm weather the coil frequency will be higher more feed and more algae growth than in case of colder weather Other causes of a too high coil frequency are a pond pump that is too large too...

Page 9: ...ing the parameters is done at own risk in case the power supply is connected Take care of electrical hazard when opening The control cabinet must be connected to an approved earthed socket The electronics must be installed vertically The electronics may not be assembled unprotected during rain Per connected side a maximum of 660 W of auxiliary equipment may be connected Functions of the green butt...

Page 10: ...float upside down for the drum section at the inlet 1st chamber Please note The float must be installed in reverse because here the circuit is to work reversely And the upper blue caps must be removed If the water rises for the drum filter it becomes polluted and the rinse cycle must be activated If in the reversed situation the float goes up and stays up the system should deactivate after 30 seco...

Page 11: ...ance and cleaning The filters are low maintenance However maintenance and inspection tasks below are required for proper functioning Check the correct functioning of the float every month Perform a manual rinse every month and check whether the nozzles perform good spraying A nozzle may get clogged or calcified Also the rinse pump may perform less pressure Clean the nozzles if necessary Clean the ...

Reviews: