PLEASE NOTE! ROTATING PARTS! 
AUTOMATIC RESTART! 

Take adequate measures to ensure that 
all rotating parts are secured against 
physical contact whenever the filter is in 
operation. Rotating parts may make the  

  operation of the machine a source of  
  danger for the service staff. 
  

CAUTION! 

Before connecting the filter, make sure it 
is not damaged. Carefully check the 
power cables and plugs before 
connecting them. 

 

Please note:

  

In case of assembly works, disconnect 
all plugs of the device from the power 
supply. Also plugs of other equipment 
that are in contact with water, must be 
removed. 

Please note:

  

Never put your hands in the water before the plug has 
been removed from the socket. This applies to all electric 
equipment that is immersed or in contact with water.  

Please note: 

Keep out of reach of children before and during assembly. 
Only suitable for people who are aware of the possible 
dangers of this device. 

Please note:  

Never try to stop the drum with your hands when it is 
rotating. 

Please note:  

Ensure that the rinse pump always has sufficient water 
during operation. It should not run dry.  

Please note:  

The drive motor and all electrical connections may not 
come in contact with water. If this happens, you must 
ensure that everything is thoroughly dry before taking 
the filter back into use.  

Please note: 

The control and rinse pump of this drum filter may only 
be connected to an earthed socket. This socket must be 
equipped with a 30mA residual current device. 

4. USAGE OF THE FILTER 

Use the filter only when no body parts are in contact with 
the water! Before touching the water you must always  
disconnect the filter from the socket.  

Compare the electrical specifications on the type plate of 
the device with the specification of the connection on the 
power supply. Ensure that the device is connected to a 
socket with earth and a ground leak switch with a 
maximum residual current of 30 mA (DIN VDE 0100T739). 
Use the device only when connected to a correctly installed 
socket. 

Keep the plug and the wiring dry! Ensure that the cables 
are protected to prevent damage and consequential short-
circuit. 

 

THE ELECTRICAL WIRING AND/OR PLUGS MAY NOT 
BE CUT (THROUGH). DOING THIS WILL CAUSE THE 

MANUFACTURER’S WARRANTY TO EXPIRE 

IMMEDIATELY. 

Only use cables, installations, adapters, extension cables 
and connection cables with earthed plugs, that were 
approved for outdoor use (DIN VDE 0620) with sufficient 
cable diameter. If the wiring is damaged or broken, it 
must be replaced. Ensure that the plug will not fall into the 
water or get wet. A wet plug must be cleaned by use of 
demineralised water and dried. Protect the plug and cables 
against heat, oil, UV-light and sharp corners. The 
manufacturer is not responsible in any way for any 
damage, caused by incorrect installation or as a result of 
carelessness of the user or installer. 

The cable may not be altered or replaced. Electrical 
installations must always comply with the national and 
international requirements/guidelines. Never open the 
casing of the control electronics. Never make technical 
modifications. Use only original parts and accessories, as 
set out in this manual. Only authorised dealers are 
empowered to perform repairs.  

Never use the filter with other liquids than water. 

5. Application fields 

The Bio-drums or drum filters are suitable for the filtration 
of fresh or slightly brackish water.  
Temperature water: 4-40 °C. 
Ambient temperature: 2 °C to +50 °C  
Protection class Electronics: IP54 

6. Installation/Connection 

Carefully read the manual before installing the filter. 
Damage as a result of failing to properly observe the 
manual, will not be covered by the warranty. 

When unpacking the filter, check whether all parts are 
complete and undamaged. Any identified damage must be 
reported to your supplier within 24 hours. Check the filter 
for damage before you put it into service. Do not use the 
filter if it is damaged. If the filter has been used and is 
damaged, the warranty and liability will expire. 

Summary of Contents for Bio100

Page 1: ...1 Misprints and printing errors reserved INSTALLATION AND USER GUIDE FOR MAKOI DRUM FILTERS AND BIODRUMS Scan the QR code for even more information ...

Page 2: ... 5 7 Commissioning of the filter 6 7 1 Positioning the filter 6 7 2 Connecting gravity 6 7 2 1 Setting of sensor float 7 7 2 3 Connecting rinse pump 7 7 2 4 Connecting motor drum filter 8 7 2 5 Coil frequency 8 7 2 6 Control electronics 9 7 2 7 Control electronics for Drum 100 and Bio drum 200 with flushing channel connection 10 7 3 Connecting pump fed system 10 7 3 1 Installation of float 10 7 3 ...

Page 3: ...ith regard to the usage and the suitability for an application will be accepted only if they fall within the Ma koi specifications specified in writing as for instance stated in this manual Any other verbal agreements for instance during preparatory discussions advertisement etc in relation to the product are valid only in case what was pledged is an integral part of a written agreement Only the t...

Page 4: ...bject to modification The specifications of the filter offer will prevail and are guaranteed 3 GENERAL 3 1 Description of the drum filter The Bio drum and or the drum filter consists of a drum sieve that is driven by an electro motor Additionally control electronics and a rinse pump are included The drum filter serves to filter and discharge floating particles dirt particles and algal remains Rega...

Page 5: ...h a maximum residual current of 30 mA DIN VDE 0100T739 Use the device only when connected to a correctly installed socket Keep the plug and the wiring dry Ensure that the cables are protected to prevent damage and consequential short circuit THE ELECTRICAL WIRING AND OR PLUGS MAY NOT BE CUT THROUGH DOING THIS WILL CAUSE THE MANUFACTURER S WARRANTY TO EXPIRE IMMEDIATELY Only use cables installation...

Page 6: ...cs contains switching components and must be placed in an interference free room Certain pumps or UV units may adversely affect the functioning of the electronics In case of frost the filter must be protected against freezing If the filter is being activated outdoors all pipes must be empty If the filter remains operative the pipes for the rinse water must be protected against freezing Damage as a...

Page 7: ...ged This is indicated on the display Siemens Logo in the Electronics Cabinet 7 2 1 Setting for sensor float Upon delivery the sensor has already been installed for use as gravity and in such a way that it will function properly in most situations Still you will need to check on proper functioning after installation and adjust the float in the best way possible If the float is in lowest position 4 ...

Page 8: ... frequency Make sure that the coil frequency is not too high If the drum is installed in an existing system the coil frequency will be high over the first days weeks because the pond is being cleaned In case of warm weather the coil frequency will be higher more feed and more algae growth than in case of colder weather Other causes of a too high coil frequency are a pond pump that is too large too...

Page 9: ...ing the parameters is done at own risk in case the power supply is connected Take care of electrical hazard when opening The control cabinet must be connected to an approved earthed socket The electronics must be installed vertically The electronics may not be assembled unprotected during rain Per connected side a maximum of 660 W of auxiliary equipment may be connected Functions of the green butt...

Page 10: ...float upside down for the drum section at the inlet 1st chamber Please note The float must be installed in reverse because here the circuit is to work reversely And the upper blue caps must be removed If the water rises for the drum filter it becomes polluted and the rinse cycle must be activated If in the reversed situation the float goes up and stays up the system should deactivate after 30 seco...

Page 11: ...ance and cleaning The filters are low maintenance However maintenance and inspection tasks below are required for proper functioning Check the correct functioning of the float every month Perform a manual rinse every month and check whether the nozzles perform good spraying A nozzle may get clogged or calcified Also the rinse pump may perform less pressure Clean the nozzles if necessary Clean the ...