background image

 

Makim Makine Teknolojileri A.Ş. All rights reserved                                                                .                                                                           

 

Kullanım Kılavuzu

 

 

Two single hiddengate(1 mechanism 

flap turnstile) creates 1 bidirectional 

lane. Control panel could be 

entegrated in either one.

 

2 single and 1 double hiddengate 

creates two bidirectional lanes. There will 

be two control panels. You could either 

entegrate control panels to 2 single units, 

or both control panels to 1 double unit.. 

 

On the left picture,4 lanes are 

shown created with 2 single 

and 3 double units. 

 

 

4.T300 HG120 FEATURES 

 
4.1 LANE ALTERNATIVES 

For the hiddengate type of turnstiles, you should arrange the lanes shown as below in order for 
people to pass. 

    

SINGLE LANE:  

 

 
 
 
 
 
 
 
 
 
 
 
 
 

   DOUBLE LANE:

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

MULTIPLE LANES:

 

 

 

 
 
 
 
 
 
 

 

 

Summary of Contents for T300 HG120

Page 1: ...TURNSTILES ACCESS CONTROL SYSTEMS CO T300 HG120 MOTORIZED TURNSTILE INSTALLATION AND USER MANUAL VERSION V2 00 OCAK 2012 ANKARA...

Page 2: ...T300 HG120 HIDDENGATE TECHNICAL SPECIFICATIONS 4 4 T300 HG120 FEATURES 5 4 1 LANE ALTERNATIVES 5 4 2 SYMBOLS 6 4 3 WORKING PRINCIPLE 7 4 4 UNAUTHORIZED ENTRY 7 5 CONTROL PANEL AND CONTROL PANEL PARTS...

Page 3: ...anger for the attending person 9 Use moist duster while cleaning the hiddengate 10 Dangerous materials for hiddengate should not be used with aim of cleanence 11 Keep hiddengate away from extremely ho...

Page 4: ...ional Special Patterned Glass Top Optional Body AISI 304 EN 1 4301 Stainless Steel AISI316 EN 1 4401 Optional AISI316L EN 1 4404 Optional Chassis 3mm HRP ST37 Galvanized PowderCoated Wings 15 mm Plexy...

Page 5: ...tes two bidirectional lanes There will be two control panels You could either entegrate control panels to 2 single units or both control panels to 1 double unit On the left picture 4 lanes are shown c...

Page 6: ...Control panel locations are shown in above picture You can increase lane quantity like that single double double single During installation give the electricity to the unit with contol panel Dashed l...

Page 7: ...ings can be both one by one and ensuingly If more than one authorizations are given those will be added to the memory and the same quantity of passages will be allowed For this 30 people can pass ensu...

Page 8: ...rmitted entry Wings will be closed to both ways in this situation and warning buzzer will be on If unauthorized person leaves the lane the wings will be opened for authorized one STANDING UNPERMITTED...

Page 9: ...NO PART NO EXPLANATION PIECES 1 B00A0738 BUZZER DASHED 24V AURAL WARNING 1 2 A00B2771 MAK M HIDDENGATE ELECTRONIC CARD V_01 1 3 A00B0598 MEAN WELL NES 100 24 SMPS POWER SUPPLY 24V 4 5A 1 4 A00A9400 SI...

Page 10: ...5 2 2 POWER SUPPLY SAFETY INSTRUCTIONS 1 Never take off the safety cover on the power supply 2 While making any arrangements take into consideration all the warnings on the safety cover and power supp...

Page 11: ...t bit and clean the dust inside the holes with help of air PICTURE 4 5 Locate the fixing plugs in the holes by joeing If the floor is not solid joe the fixing plugs after pouring chemical grout and wa...

Page 12: ...usage environment and climate conditions Do not use corrosive chemical matters while doing maintenance While cleaning sensor Windows use a clean dry fabric and do not make any compress Outer steel bod...

Page 13: ...stay open 1 There may be preventing jamming while closing 1 Check it by hand 2 There may be fault on the program 2 Check the program 3 There may be fault on the sensors 3 Change the sensors Wings do n...

Page 14: ...53 safety Of Machinery Guards General requirements for the design and construction of fixed and guards TS EN 294 safety of machinery Safety distances to prevent danger zones being reached by the upper...

Reviews: