background image

 

Makim Makine Teknolojileri A.Ş. All rights reserved                                                                .                                                                           

 

Kullanım Kılavuzu

 

 

BEFORE YOU START

 

 Thank you for purchasing T300 HG120 Motorized Turnstile and we advise you to read this  manual 
carefully in order to use the machine longer time without problem. Please keep the user manual to 
benefit when need arises. 

 

1.HIDDENGATE SAFETY INSTRUCTIONS 

 

Before you install and use the hiddengate, please read all the safety and maintenance instructions carefully.Turnikenizi 
kurmadan ve kullanmadan önce tüm güvenlik ve bakım önerilerini dikkatle okumanızı tavsiye ederiz. 

1.

 

You should read the user manual before installing the hiddengate. 

2.

 

For safety reasons, don’t open the hiddengate yourself. Maintenance must be done only by the authorized service or the 
seller agent. The modifications made by user might pose danger fort he machine and people. 

3.

 

Deformed hiddengates should not be operated and authorized service must be indormed immediately. 

4.

 

 Specified power and voltage values in the technical specifications part must be adapted. 

5.

 

Before you energize the hiddengate after any deformation or maintenance, check the accuracy of power supply 
and control card connections.  

6.

 

Use the parts and accesories approved by the manufacturer compay. 

7.

 

In case of any problem, cut off the electricity connections of turnstile and inform the authorized service.  

8.

 

Cut off the electricity connections while doing maintenance and cleaning. Otherwise, it may pose danger for the 
attending person. 

9.

 

Use moist duster while cleaning the hiddengate. 

10.

 

Dangerous materials for hiddengate should not be used with aim of cleanence.  

11.

 

Keep hiddengate away from extremely hot and febrile environments. Extreme heat may cause failure in the system. Do 
not operate the hiddengate for long time under direct sun light.  

12.

 

Hiddengate should not be used in high magnetic fields. 

13.

 

Do not expose the hiddengate extreme water. Do not operate it under direct rain. 

 

 

2

.

HIDDENGATE USAGE INSTRUCTIONS

  

1.

 

Hiddengate is designed for only one person passage each time. More than one person should not try to pass the lane at 
the same time. 

2.

 

In the event of the system not working thoroughly, actions posing danger to the system must be avoided. 

3.

 

In the event of any failure, in order to prevent more harm to the hiddengate, ungear the system or do not use it.. 

4.

 

As the hiddengate will not detect any object not higher than itself, it could be closed to the user in this case. 

5.

 

Do not wait for long time on the passage lanes.  

6.

 

Avoid from violent passings through hiddengate, do not turn to sides while passing. 

7.

 

For unaccompanied children, animals and objects like street toy cars, there may come the buzzer voice. Only with 
accompany of adults will the hiddengate be opened. 

8.

 

All operations on the equipments must be done by technical personnel. Any failures caused by unauthorized people or 
non-technical personnel will be out of warranty  coverage of manufacturer. 

Manufacturer does not accept any responsibility for the failures or woundings occured because of  not 
confirming to the above specified Safety and Usage Instructions. 

 

Summary of Contents for T300 HG120

Page 1: ...TURNSTILES ACCESS CONTROL SYSTEMS CO T300 HG120 MOTORIZED TURNSTILE INSTALLATION AND USER MANUAL VERSION V2 00 OCAK 2012 ANKARA...

Page 2: ...T300 HG120 HIDDENGATE TECHNICAL SPECIFICATIONS 4 4 T300 HG120 FEATURES 5 4 1 LANE ALTERNATIVES 5 4 2 SYMBOLS 6 4 3 WORKING PRINCIPLE 7 4 4 UNAUTHORIZED ENTRY 7 5 CONTROL PANEL AND CONTROL PANEL PARTS...

Page 3: ...anger for the attending person 9 Use moist duster while cleaning the hiddengate 10 Dangerous materials for hiddengate should not be used with aim of cleanence 11 Keep hiddengate away from extremely ho...

Page 4: ...ional Special Patterned Glass Top Optional Body AISI 304 EN 1 4301 Stainless Steel AISI316 EN 1 4401 Optional AISI316L EN 1 4404 Optional Chassis 3mm HRP ST37 Galvanized PowderCoated Wings 15 mm Plexy...

Page 5: ...tes two bidirectional lanes There will be two control panels You could either entegrate control panels to 2 single units or both control panels to 1 double unit On the left picture 4 lanes are shown c...

Page 6: ...Control panel locations are shown in above picture You can increase lane quantity like that single double double single During installation give the electricity to the unit with contol panel Dashed l...

Page 7: ...ings can be both one by one and ensuingly If more than one authorizations are given those will be added to the memory and the same quantity of passages will be allowed For this 30 people can pass ensu...

Page 8: ...rmitted entry Wings will be closed to both ways in this situation and warning buzzer will be on If unauthorized person leaves the lane the wings will be opened for authorized one STANDING UNPERMITTED...

Page 9: ...NO PART NO EXPLANATION PIECES 1 B00A0738 BUZZER DASHED 24V AURAL WARNING 1 2 A00B2771 MAK M HIDDENGATE ELECTRONIC CARD V_01 1 3 A00B0598 MEAN WELL NES 100 24 SMPS POWER SUPPLY 24V 4 5A 1 4 A00A9400 SI...

Page 10: ...5 2 2 POWER SUPPLY SAFETY INSTRUCTIONS 1 Never take off the safety cover on the power supply 2 While making any arrangements take into consideration all the warnings on the safety cover and power supp...

Page 11: ...t bit and clean the dust inside the holes with help of air PICTURE 4 5 Locate the fixing plugs in the holes by joeing If the floor is not solid joe the fixing plugs after pouring chemical grout and wa...

Page 12: ...usage environment and climate conditions Do not use corrosive chemical matters while doing maintenance While cleaning sensor Windows use a clean dry fabric and do not make any compress Outer steel bod...

Page 13: ...stay open 1 There may be preventing jamming while closing 1 Check it by hand 2 There may be fault on the program 2 Check the program 3 There may be fault on the sensors 3 Change the sensors Wings do n...

Page 14: ...53 safety Of Machinery Guards General requirements for the design and construction of fixed and guards TS EN 294 safety of machinery Safety distances to prevent danger zones being reached by the upper...