Note:
The push-button switch
"Reset"
located at the safety system must be activated after an
activation of the external emergency stop device!
Aftercooling
If the engine is stopped under load, it must be aftercooled for approximately
5 min.
to prevent
steam bubble formation.
•
If the engine is separated from the
cooling water pump:
Let electrical pumps go on running:.
•
It the pumps are mounted at the engine:
Switch on backing pump or circulation
pump of the preheating device.
•
Engines with mutual preheating:
Switch the corresponding valve according
to pipe plan.
Resumption of engine operation after short operating stop
To prevent heat collections shortly before or immediately after stopping the engine, switch on the
system circulations and keep the engine at operating temperature or preheating temperature (see
) according to the interruption period and type of fuel.
In heavy oil operation a change-over to distillate fuel (see
) is only necessary if
maintenance work on the injection system are planned or if operation is to be continued with a
lower load during a longer period as is the case in some applications (see
•
Switch on preheating device.
•
Put cooling water circulation pump into operation.
•
In the case of preheating through different running engines open corresponding shut-off
valves.
•
Continue to operate fuel system in the heavy oil/distillate operation as during engine
operation to keep it at a temperature ready for operation: Circulation pump, fuel preheating
via viscosity meter, reversible flow filter - if present - is in operation. Also operate fuel
separator before service tank.
•
Cooling oil pump for nozzles stays in operation if no maintenance work on injection valves
has to be performed.
Summary of Contents for M20
Page 5: ...Technical engine data A1 M20 M601C en 31 10 2001 AA000103 1 1 Technical engine data...
Page 6: ...Governor data A1 04 en 18 02 2000 AA000097 1 1 Governor data not installed on CD Rom...
Page 11: ...Operating instructions A3 M20 M601C en 31 10 2001 AA000108 1 1 Operating instructions...
Page 30: ...Initial operation Engine A3 05 00 en 14 02 2001 BA000022 1 1 Initial operation...
Page 44: ...Operational supervision Engine A3 06 00 en 15 02 2001 BA000058 1 1 Operational supervision...
Page 64: ...Removal from operation Engine A3 07 00 en 16 02 2001 BA000094 1 1 Removal from operation...
Page 71: ...Danger of frost Engine A3 08 00 en 16 02 2001 BA000106 1 1 Danger of frost...
Page 83: ...Running in Engine A3 10 00 en 16 02 2001 BA000242 1 1 Running in...
Page 85: ...Fault tracing Engine A3 11 00 en 19 02 2001 BA000130 1 1 Fault tracing...
Page 91: ...Emergency operation Engine A3 12 00 en 19 02 2001 BA000142 1 1 Emergency operation...
Page 102: ...Operating media A4 en 31 10 2001 AA020105 1 1 Operating media...
Page 106: ...Regulations and care Engine A4 05 00 en 21 02 2001 BA000158 1 1 Regulations and care...
Page 137: ...Maintenance A5 en 31 10 2001 AA000026 1 1 Maintenance...
Page 166: ...Periodical schedule Heavy fuel A5 04 02 M20 en 31 10 2001 AA021679 8 8...
Page 242: ...Bearing Shells Inspection Evaluate A5 05 02 03 07 01 M20 en 13 06 1997 IB001449 3 4 02 1 2 3...
Page 243: ...Bearing Shells Inspection Evaluate A5 05 02 03 07 01 M20 en 13 06 1997 IB001449 4 4 02 4 5 6...
Page 435: ...Table of contents A6 01 en 31 10 2001 AA020050 1 1 Tools A6 Table of contents A6 01...