![MAK M20 Operating Instructions Manual Download Page 410](http://html1.mh-extra.com/html/mak/m20/m20_operating-instructions-manual_3784461410.webp)
en / 03.06.1998
IB001418
3/4
08
2.3.4
Put the filter element in a suitable cleansing liquid.
The cleansing liquid must only reach up
to the bottom edge of the element plate (Fig. 3/2) so that no contaminated liquid can
enter into the filter candles (14) from the top. The top area of the gauze must be visible in
the filter candles.
Soaking time as required by the suppliers of the cleanser, but maximum
4 hours.
2.3.5
Take the filter element out of cleansing liquid and blow through filter candles (14)
with compressed air (
Fig. 2
/W1) (sequence of operations 2.2.4).
Air pressure max.
10 bar
.
2.3.6
Put the filter element again in clean cleansing liquid, allow to drip dry and blow through
with compressed air (W1). Turn filter element upside down, so that the cleansing liquid can
drain off.
2.3.7
Check the filter candles occasionally for damage (sequence of operations
2.4
).
2.3.8
Put the filter element in the chamber, fit the cover and renew the gasket if necessary.
2.3.9
Fill the filter chamber and vent it (see the plate on the filter cover).
2.4
Cleaning the filter candles in the case of heavy soiling.
Note:
In the case of heavy soiling of the filter element (paint spots, incrustation, tar deposits,
fibers, chips), remove filter candles and clean them individually.
2.4.1
Soak the filter element in cleansing liquid (max. 4 hours).
2.4.2
Disconnect the base plate and carefully remove the protective shell from the filter element.
2.4.3
Remove the filter candles (14) with the drift (
Fig. 3
/W2) downwards and tilt them out.
Re-
move the O-ring (25) between the filter candles and the element plate (2), because O-rings
must not have contact with the cleansing liquid.
2.4.4
Inspect the filter candles and renew them in the case of damage and/or heavy folding of
the gauze.
Attention:
The damage on only one
filter candles means malfunction of the whole element.
Do not put the removed filter candles one upon another; this might damage the gauze.
2.4.5
Connect the cleaning pistol (
Fig. 2
/W1) to the compressed air supply.
Air pressure
max. 10 bar
.
Summary of Contents for M20
Page 5: ...Technical engine data A1 M20 M601C en 31 10 2001 AA000103 1 1 Technical engine data...
Page 6: ...Governor data A1 04 en 18 02 2000 AA000097 1 1 Governor data not installed on CD Rom...
Page 11: ...Operating instructions A3 M20 M601C en 31 10 2001 AA000108 1 1 Operating instructions...
Page 30: ...Initial operation Engine A3 05 00 en 14 02 2001 BA000022 1 1 Initial operation...
Page 44: ...Operational supervision Engine A3 06 00 en 15 02 2001 BA000058 1 1 Operational supervision...
Page 64: ...Removal from operation Engine A3 07 00 en 16 02 2001 BA000094 1 1 Removal from operation...
Page 71: ...Danger of frost Engine A3 08 00 en 16 02 2001 BA000106 1 1 Danger of frost...
Page 83: ...Running in Engine A3 10 00 en 16 02 2001 BA000242 1 1 Running in...
Page 85: ...Fault tracing Engine A3 11 00 en 19 02 2001 BA000130 1 1 Fault tracing...
Page 91: ...Emergency operation Engine A3 12 00 en 19 02 2001 BA000142 1 1 Emergency operation...
Page 102: ...Operating media A4 en 31 10 2001 AA020105 1 1 Operating media...
Page 106: ...Regulations and care Engine A4 05 00 en 21 02 2001 BA000158 1 1 Regulations and care...
Page 137: ...Maintenance A5 en 31 10 2001 AA000026 1 1 Maintenance...
Page 166: ...Periodical schedule Heavy fuel A5 04 02 M20 en 31 10 2001 AA021679 8 8...
Page 242: ...Bearing Shells Inspection Evaluate A5 05 02 03 07 01 M20 en 13 06 1997 IB001449 3 4 02 1 2 3...
Page 243: ...Bearing Shells Inspection Evaluate A5 05 02 03 07 01 M20 en 13 06 1997 IB001449 4 4 02 4 5 6...
Page 435: ...Table of contents A6 01 en 31 10 2001 AA020050 1 1 Tools A6 Table of contents A6 01...