4. Button Function

4.1. MODE and REL Button

•  Press the 

MODE 

Button to select AC/DC Voltage, AC/DC Current, 

Frequency, Duty Cycle, Ohms, Diode Test, Continuity or Capacitance, 
Temperature, NCV and Live.

•  Press the 

REL 

Button for >2 second to turn on or off the Relative function.

•  The Relative function zeros out the reading on the display and stores it as 

a reference, subsequent readings will be displayed as the relative 
difference between the actual measurement and the stored reference 
value.

Note: 

REL does not work on Frequency, Diode Test, Continuity, NCV, Live.

4.2. RANGE Button

•  When the meter is first turned on, it automatically goes into Auto Ranging.
•  This automatically selects the best range for the measurements being  

made and is generally the best mode for most measurements.

•  For measurement situations requiring that a range be manually selected, 

perform the following:

1. Press the 

RANGE 

Button, the “

AUTO

” display indicator will turn off.

2. Press the 

RANGE 

Button to step through the available ranges until you 

select the range you want.

3. Press and hold the 

RANGE 

Button for 2 seconds to exit the Manual 

Ranging mode and return to Auto Ranging.

4.3. 

MAX/MIN Button

1. Press the 

MAX/MIN 

Button to activate the MAX/MIN mode, the “

MAX

” 

indicator will appear on the LCD display, the meter will display and hold the 
maximum reading and will update when a higher “max” occurs.

2. Press the 

MAX/MIN 

Button again to view the lowest reading, the “

MIN

” 

indicator meter will appear on the LCD display, the meter will display and 
hold the minimum reading and will update when a lower “min” occurs.

3. Press and hold the 

MAX/MIN 

Button to end MAX/MIN and return to normal 

operation.

Note: 

The meter does not auto range when the MAX/MIN mode is active, the 

display will read OL if the range is exceeded. When this occurs, exit 
MAX/MIN and use the RANGE button to select a high range. MAX/MIN does 
not work on Frequency, Duty Cycle, Diode Test, Continuity and Capacitance.

Summary of Contents for MT876

Page 1: ...MT876 600V AC DC TRMS MULTIMETER INSTRUCTION MANUAL...

Page 2: ...2...

Page 3: ...3 Contents Page no...

Page 4: ...asurements Before changing functions using the selector switch always disconnect the test leads from the circuit under test Comply with all applicable safety codes Use approved personal protective equ...

Page 5: ...ected to a circuit point at which the voltage exceeds 600 VAC or VDC This WARNING symbol indicates a potentially hazardous situation which if not avoided could result in death or serious injury This C...

Page 6: ...Lighting circuits in commercial buildings Feeder lines in industrial plants Any device or branch circuit that is close to a Cat III source The measurement category CAT rating and voltage rating is de...

Page 7: ...ATIVE Button 4 RANGE Button 5 MAX MIN Button 6 HOLD Backlight Button 7 Function Switch 8 10A Input Jack 9 COM Input Jack 10 Positive Input Jack 11 Non Contact Voltage Detector 12 Lanyard Hole 13 Test...

Page 8: ...8 Relative Mode 9 Non Contact AC Voltage Detection 10 Live Neutral Wire Measurement Function 11 Degree Celsius Degree Fahrenheit 12 Units of Measure List 13 Measurement Reading 14 Low Battery 15 Batte...

Page 9: ...g 1 Press the RANGE Button the AUTO display indicator will turn off 2 Press the RANGE Button to step through the available ranges until you select the range you want 3 Press and hold the RANGE Button...

Page 10: ...the Backlight function 4 5 Auto Power Off The auto off feature will turn the meter off after 15 minutes To disable the auto power off feature hold down the MODE Button and turn the meter on 4 6 Low B...

Page 11: ...Set the rotatory function switch to the VAC DC Position 2 To select AC or DC voltage press the MODE Button until the AC or DC symbol appears on the LCD display 3 Insert the black test lead banana plug...

Page 12: ...the negative COM Input Jack Insert the red test lead banana plug into the Positive Input Jack 3 Touch the test probe tips to the circuit under test 4 Read the frequency on the display 5 Press the But...

Page 13: ...y function switch to the mA Position and Insert the red test lead into the Positive Input Jack 4 For current measurements up to 4000 A AC DC set the rotary function switch to the A Position and Insert...

Page 14: ...LCD display 3 Insert the black test lead banana plug into the negative COM Input Jack Insert the red test lead banana plug into the Positive Input Jack 4 Touch the test lead probes to the component un...

Page 15: ...3 Insert the black test lead banana plug into the negative COM Input Jack Insert the red test lead banana plug into the Positive Input Jack 4 Touch the test lead probes to the diode under test 5 Forw...

Page 16: ...ymbol appears on the LCD display 3 Insert the black test lead banana plug into the negative COM Input Jack Insert the red test lead banana plug into the Positive Input Jack 4 Touch the test lead probe...

Page 17: ...rds 1 Set the rotary function switch to the CAP Position 2 Press the MODE Button until the nF symbol appears on the LCD display 3 Insert the black test lead banana plug into the negative COM Input Jac...

Page 18: ...n to indicate C or F 3 Connect the temperature probe to the banana plug adapter note the and markings on the adapter 4 Connect the adapter to the meter making sure the side goes into the COM Input Jac...

Page 19: ...ight will not flash and the buzzer sound will not trigger 5 According to the detected signal strength LCD displays different horizontal lines When the signal is strongest the LCD displays four horizon...

Page 20: ...tton to select readings in Live 3 Insert the red test lead into the Positive Input Jack 4 Do not connect any test leads or conductors to the other two terminals 5 Touch the red test lead probes to the...

Page 21: ...Position 2 Insert the black test lead banana plug into the negative COM Input Jack Insert the red test lead banana plug into the Positive Input Jack 3 Connect the red test lead to the positive side o...

Page 22: ...y WARNING To avoid electric shock disconnect the test leads from any source of voltage before removing battery cover WARNING To avoid electric shock do not operate the meter until the battery cover is...

Page 23: ...01V 400 0V 0 1V 400 0mV 4 000V 0 5 8 digits DC Voltage 0 1mV 0 001V 600V 1V 40 00mA 0 01mA 400 0mA 0 1mA 400 0 A 4000 A 1 0 5 digits AC True RMS Current 0 1 A 1 A 4 000A 0 001A 10 00A 0 01A 1 2 8 digi...

Page 24: ...Range Accuracy Function Resolution 9 999 F 0 001 F 99 99 F 0 01 F 99 99nF 999 9nF 3 0 5 digits Capacitance 0 01nF 0 1nF 999 9 F 0 1 F 9 999mF 0 001mF 3 5 5 digits 5 0 20 digits 4 0 10 digits 99 9mF 0...

Page 25: ...teries Two AAA 1 5V batteries Fuse 10A 600V fast acting Fuse 500mA 600V fast acting Fuse Operating Environment 5 to 40 C 41 to 104 F Storage Environment 10 to 50 C 14 to 122 F Operating Humidity Max 8...

Page 26: ......

Page 27: ......

Page 28: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD...

Reviews: