5.11.
Battery Test
WARNING:
Do not connect to circuits that exceed 20V AC RMS or
20V DC when the meter is set to 1.5V or 9V BATT Position.
1. Set the rotary function switch to the
1.5V
or
9V
BATT. Position.
2. Insert the black test lead banana plug into the negative
COM
Input Jack; Insert the red test lead banana plug into the
Positive
Input Jack.
3. Connect the red test lead to the positive side of the battery and
the black test lead to the negative side of the battery.
4. Read the voltage in the display.
Good
Weak
Bad
9V battery
>8.2V
7.2 to 8.2V
<7.2V
1.5V battery
>1.35V
1.22 to 1.35V
<1.22V